Service manual
SiBE041102_A Outdoor Unit
Removal Procedure 129
2
Cut the clamp.
When reassembling, clamp
the outdoor heat exchanger
thermistor and the harness
of the electronic expansion
valve coil.
3
Release the outdoor
heat exchanger
thermistor.
Take care not to lose the clip
of thermistor.
Step
Procedure Points
(R14519)
Outdoor
heat exchanger thermistor
(R14520)
Clip
Clip
(R11268)
Thermistor