Service manual

SiUS041111 Functions
List of Functions 3
Category Functions
FTXN15/18/24KVJU
RKN15/18/24KEVJU
FTXN15/18/24KVJU
RXN15/18/24KEVJU
Category Functions
FTXN15/18/24KVJU
RKN15/18/24KEVJU
FTXN15/18/24KVJU
RXN15/18/24KEVJU
Basic Function Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter
Operation Limit for Cooling (°FDB)
50 ~
114.8
50 ~
114.8
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°FWB)
5 ~
64.4
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control 
Titanium Apatite Photocatalytic
Air-Purifying Filter

Standby Electricity Saving
Compressor Oval Scroll Compressor Air Filter (Prefilter) 
Swing Compressor  Wipe-Clean Flat Panel 
Rotary Compressor Washable Grille
Reluctance DC Motor  MOLD PROOF Operation
Comfortable
Airflow
Power-Airflow Louver (Horizontal Blade)
Good-Sleep Cooling Operation
Power-Airflow Dual Louvers 
Power-Airflow Diffuser Timer WEEKLY TIMER
Wide-Angle Fins (Vertical Blades)  24-Hour ON/OFF TIMER 
Vertical Auto-Swing (Up and Down)  NIGHT SET Mode 
Horizontal Auto-Swing (Right and Left) Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) 
3-D Airflow Self-Diagnosis (Digital, LED) Display 
COMFORT AIRFLOW Operation Wiring Error Check Function
Comfort
Control
Auto Fan Speed 
Anticorrosion Treatment of Outdoor
Heat Exchanger

Indoor Unit Quiet Operation 
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
——
NIGHT QUIET Mode (Automatic) H/P, C/O Compatible Indoor Unit 
Outdoor Unit Quiet Operation (Manual) Flexible Power Supply Correspondence
INTELLIGENT EYE Operation Chargeless
32.8 ft 32.8 ft
Quick Warming Function
(Preheating Operation)
Either Side Drain (Right or Left) 
Hot-Start Function Power Selection
Automatic Defrosting
Low Temperature Cooling Operation
(–15°C) (5°F)

Operation
Automatic Operation
°F/°C Changeover R/C Temperature
Display (factory setting : °F)

Program Dry Function Remote
Control
5-Room Centralized Controller (Option) 
Fan Only 
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)

Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Remote Control Adaptor
(Normal Open Contact) (Option)

Inverter POWERFUL Operation  DIII-NET Compatible (Adaptor) (Option) 
Priority-Room Setting Remote
Controller
Wireless 
COOL / HEAT Mode Lock Wired (Option) 
HOME LEAVE Operation
ECONO Operation
Indoor Unit ON/OFF Button 
Signal Receiving Sign 
R/C with Back Light 
Temperature Display
Note: : Holding Functions
— : No Functions