Service manual
SiEBE12-625 Check
Service Diagnosis 243
6.1.6 Installation Condition Check
Check No.07
Installation condition check
Normal
Change the position of the air
discharge grille or the
installation location.
Change the position of the air
discharge grille or the
installation location.
Clean the heat exchanger.
Change the installation
location or direction.
Check the outside air
temperature (temperature of air
taken in by the outdoor unit).
(The outside air temper
ature
shall be 46°C or lower.)
Check
the allowable
dimensions of the air suction
and discharge
area.
Is the
air flow blocked by
obstacles or winds blowing in
the opposite
direction?
(R3048)
Abnormal
YES
YES
YES
Does the
discharged air from
other outdoor unit cause an
increase of the suction air
temperature?
NO
NO
NO
Is the heat exchanger
very dirty?