Specifications
Table Of Contents
- Cover
- Table of Contents
- Part 1 List of Functions
- Part 2 Specifications
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Part 4 Function and Control
- Part 5 Operation Manual
- Part 6 Service Diagnosis
- 1. Caution for Diagnosis
- 2. Problem Symptoms and Measures
- 3. Service Check Function
- 4. Code Indication on the Remote Controller
- 5. Troubleshooting
- 5.1 Indoor Units
- 5.2 Outdoor Units
- 5.3 Indoor Unit PCB Abnormality A1
- 5.4 Freeze-up Protection Control or High Pressure Control A5
- 5.5 Fan Motor or Related Abnormality A6
- 5.6 Thermistor or Related Abnormality (Indoor Unit) C4,C9
- 5.7 Front Panel Open / Close Fault C7
- 5.8 Signal Transmission Error (between Indoor and OutdoorUnit) U4
- 5.9 Unspecified Voltage (between Indoor and Outdoor Units) UA
- 5.10 Freeze-up Protection Control A5
- 5.11 Outdoor Unit PCB Abnormality E1
- 5.12 OL Activation (Compressor Overload) E5
- 5.13 Compressor Lock E6
- 5.14 DC Fan Lock E7
- 5.15 Input Over Current Detection E8
- 5.16 Discharge Pipe Temperature Control F3
- 5.17 High Pressure Control in Cooling F6
- 5.18 Compressor Sensor System Abnormality H0
- 5.19 Position Sensor Abnormality H6
- 5.20 CT or Related Abnormality H8
- 5.21 Thermistor or Related Abnormality (Outdoor Unit) P4,J3,J6,J8,J9,H9
- 5.22 Electrical Box Temperature Rise L3
- 5.23 Radiation Fin Temperature Rise L4
- 5.24 Output Over Current Detection L5
- 5.25 Insufficient Gas U0
- 5.26 Low-voltage Detection or Over-voltage Detection U2
- 5.27 Signal Transmission Error (on Outdoor Unit PCB) U7
- 5.28 Anti-icing Function in Other Rooms / UnspecifiedVoltage (between Indoor and Outdoor Units) UA,UH
- 6. Check
- Part 7 Removal Procedure
- Part 8 Others
- Part 9 Appendix
- Index
- Drawings & Flow Charts

Instruction SiBE12-713
198 Operation Manual
2.2.10 WEEKLY TIMER Operation
19
WEEKLY TIMER Operation
Up to 4 timer settings can be saved for each day of the week.
To use WEEKLY TIMER operation
•
Make sure the day of the week and time are set.
If not, set the day of the week and time. (page 8.)
•
The following procedure is to make a reservation
on Monday for Tuesday 6:00 am/27˚C.
1. Press “ button”.
• The day of the week and the reservation
number will be displayed.
• 1 to 4 settings can be made per day.
2.
Press the “SELECT button” to select the desired
day of the week and reservation number.
•
Pressing the “SELECT button” changes the
reservation number and the day of the week.
3. Press “NEXT button”.
• The day of the week will be set.
• “ ” and “ ” blink.
4. Press “SELECT button” to select the desired mode.
• “ ” and “ ” or “ ” will flash.
• To go to the next reservation setting, select “no setting”.
5. Press “NEXT button”.
• The weekly mode will be set.
• “ ” and “ ” blink.
6. Press “SELECT button” to select the desired time.
• The time can be set between 0:00 and 23:50 in 10 minute intervals.
• Press “BACK button” to return to the mode setting.
3, 5
1
2, 4, 6
ON TIMER OFF TIMER no setting