Specifications

Wiring Diagrams Si01-406
190 Appendix
2. Wiring Diagrams
2.1 Indoor Units
FT25CV1A / FT35CV1A
FT50CV1A / FT60CV1A
C70 : RUNNING CAPACITOR
FU : FUSE
H1P
,
H2P : PILOT LAMP
M1F : FAN MOTOR
M1S : SWING MOTOR
MR2 : MAGNETIC RELAY
PCB1
,
PCB2 : PRINTED CIRCUIT BOARD
REMOTE
WIRELESS
CONTROLLER
PCB2
M1S
M
RECEIVER
SIGNAL
S26
S27
S6
LED1
H1P
HA
LED2
H2P
S21
S32
R2T
tº
SW7
R1T
tº
R1T
,
R2T : THERMISTOR
S1~S32 : CONNECTOR
SW7 : OPERATION SWITCH
SA1 : SURGE ARRESTER
V1
,
V2 : VARISTOR
X1M : TERMINAL STRIP
S7
PCB1
: PROTECTIVE EARTH
C70
1~
M1F
tº
M
V1
140ºC
S1
3.15A
FU
SA1
V2 FG
H3
H1
MR2
GRN
YLW
H2
/
GRN
NOTE
ADDRESS JUMPER IS MARKED
"JA"ON PCB1.
/
YLW
BLK
WHT
RED
X1M
2
3
1
TO OUTDOOR
UNIT
3D027406C
CONTROLLER
WIRELESS
REMOTE
PCB4
PCB3
LED1
H1P
R1T
t˚
S37
S38
LED2
H2P
PCB2
S27
S1W
RECEIVER
SIGNAL
S26
S21
S29
S28
PCB1
R2T
S32
t˚
~
RECTIFIER
1
RED
M1S
M
S6
ORG
YLW
~
PNK
5
BLU
V1
7
1
SA1
S1
3.15A
Fu
MR2
WHT
BRN
RED
BLU
ORG
V2
H2
H3
H1
INDOOR
FG
M1F
M
GRN
M1S : SWING MOTOR
SA1 : SURGE ARRESTER
Fu : FUSE
H1~H3 : HARNESS
V1
,
V2 : VARISTOR
M1F : FAN MOTOR
WHT
BLK
/
S1~S38 : CONNECTOR
MR2 : MAGNETIC RELAY
RED
H1P
,
H2P : PILOT LAMP
R1T
,
R2T : THERMISTOR
FG : FRAME GROUND
X1M : TERMINAL STRIP
YLW
S1W : OPERATION SWITCH
PCB1~PCB4 : PRINTED CIRCUIT BOARD
: PROTECTIVE EARTH
X1M
3
2
1
FIELD WIRING.
CAUTION
3
2
1
3D038655C
OUTDOOR
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.