Instruction manual
10 English
a If the operation mode of the first room is FAN
Mode, then using Heating Mode in any room
after this will give priority to heating. In this sit-
uation, the air conditioner running in FAN Mode
will go on standby.
b With the Priority Room Setting active
Contact your Daikin dealer for the operation
that corresponds to your system.
• If the total capacity of all the indoor units run-
ning exceeds the limit, the indoor unit will go
into standby mode (fan and air flow direction
remain as set). (Only for cooling-only type.)
• If another indoor unit goes into heating mode
after cooling, the unit may go into dry mode
(fan operates whisper and the air flow flaps
become horizontal).
III.THE FAN SPEED IS DIFFERENT FROM THE
SETTING.
• Pressing the fan speed control button does
not change the fan speed.
When the room temperature reaches the set tem-
perature in heating mode, the power supply from
the outdoor unit stops and the indoor unit goes
into whisper mode (in a multi system, the fan goes
back and forth between stop and whisper).
This is to prevent the cool air from being blown
directly onto anyone in the room.
IV.AIR BLOW DIRECTION IS NOT AS SPECIFIED.
• Actual air blow direction is not as shown on
the remote controller.
• Automatic swing setting does not work.
Refer to “AIR FLOW DIRECTION ADJUST”.
V. WHITE MIST COMES OUT OF A UNIT
• When humidity is high during cooling opera-
tion (In oily or dusty places)
If the inside of an indoor unit is extremely contam-
inated, the temperature distribution inside a room
becomes uneven. It is necessary to clean the
inside of the indoor unit. Ask your Daikin dealer for
details on cleaning the unit. This operation
requires a qualified service person.
• When the system is changed over to HEATING
OPERATION after DEFROST OPERATION.
Moisture generated by DEFROST becomes
steam and exists.
VI.NOISE OF AIR CONDITIONERS
• A ringing sound after the unit is started.
This sound is generated by the temperature
regulator working.
It will quiet down after about a minute.
• A continuous flow “Shuh” sound is heard
when the systems is in COOLING or DEFROST
OPERATION.
This is the sound of refrigerant gas flowing
through both indoor and outdoor units.
• A “Shuh” sound which is heard at the start or
immediately after the stop of operation or
which is heard at the start or immediately after
the stop of DEFROST OPERATION.
This is the noise of refrigerant caused by flow stop
and flow change.
• A continuous flow “Shah” sound is heard
when the system is in COOLING OPERATION
or at a stop.
The noise is heard when the drain pump is in
operation.
• A “Pishi-pishi” squeaking sound is heard
when the system is in operation or after the
stop of operation.
Expansion and contraction of plastic parts caused
by temperature change makes this noise.
VII.DUST FROM THE UNITS
• Dust may blow out from the unit after starting
operation from long resting time.
Dust absorbed by the unit blows out.
VIII.THE UNITS GIVE OFF ODORS
The unit absorbs the smell of rooms, furniture,
cigarettes, etc., and then emits them.
IX.THE LIQUID CRYSTAL OF THE REMOTE CON-
TROLLER SHOW “ ”
• It happens immediately after the main power
supply switch is turned on.
This shows that the remote controller is in normal
condition.
This continues temporary.
I. If one of the following malfunctions occurs,
take the measures shown below and contact
your Daikin dealer.
The system must be repaired by a qualified service
person.
WARNING
When the air conditioner is in abnormal con-
ditions (smell of something burning, etc),
unplug the power cord from the outlet, and
contact your dealer
Continued operation under such circumstances
may result in a failure, electric shock, and fire.
• If a safety device such as a fuse, a breaker or an
earth leakage breaker frequently actuates;
Measure: Do not turn on the main power switch.
• If the ON/OFF switch does not properly work;
Measure: Turn off the main power switch.
10. TROUBLE SHOOTING