Service Manual

Functions SiUS181631EA
8 List of Functions
Category Functions
FFQ09/12/15/18Q2VJU
with BYFQ60B3W1
FFQ09/12/15/18Q2VJU
with BYFQ60C2W1W(S)
Category Functions
FFQ09/12/15/18Q2VJU
with BYFQ60B3W1
FFQ09/12/15/18Q2VJU
with BYFQ60C2W1W(S)
Basic
Functions
Inverter (with inverter power control)
zz
Health &
Cleanliness
Auto cleaning filter
Operation limit for cooling
Air-purifying filter with photocatalytic
deodorizing function
——
Operation limit for heating
PAM control Titanium apatite deodorizing filter
Standby electricity saving Longlife filter
zz
Compressor Oval scroll compressor Air filter
Swing compressor Filter cleaning indicator
zz
Rotary compressor Wipe-clean flat panel
Reluctance DC motor Washable grille
zz
Comfortable
Airflow
Power-airflow flap (horizontal blade) MOLD PROOF operation
Power-airflow dual flaps
(horizontal blade)
——
Good-sleep cooling operation
Timer Schedule TIMER operation
z
1
z
1
Power-airflow diffuser 72-hour ON/OFF TIMER
z
2
z
2
Wide-angle louvers (vertical blades) Off Timer (power off forget prevention)
z
1
z
1
Auto-swing (up and down)
zz
NIGHT SET mode
Auto-swing (right and left) Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
zz
Individual flap control
z
1 Self-diagnosis (R/C, LED)
zz
3-D airflow Wiring error check function
COMFORT AIRFLOW operation
Anti-corrosion treatment of outdoor heat
exchanger
——
Comfort
Control
Auto fan speed
z
1
z
1
Indoor unit quiet operation Flexibility
Multi-split/split type compatible indoor
unit
zz
NIGHT QUIET mode (automatic)
OUTDOOR UNIT QUIET operation
(manual)
——
H/P, C/O compatible indoor unit
Flexible power supply correspondence
Presence and floor sensor (option)
z
1 Chargeless
Hot-start function
zz
Either side drain (right or left)
Draft prevention with sensor
zz
Power selection
Automatic defrosting
zz
°F/°C changeover R/C temperature
display (factory setting: °F)
z
1
z
1
Operation Automatic operation
zz
Program dry function
zz
Remote
Control
Remote control adaptor
(normal open pulse contact) (option)
——
Fan only
zz
Setback function
z
1
z
1
Remote control adaptor
(normal open contact) (option)
——
Lifestyle
Convenience
POWERFUL operation (non-inverter)
POWERFUL operation (inverter) DIII-NET compatible (adaptor) (option)
Priority-room setting Remote
Controller
Wireless (option)
zz
COOL/HEAT mode lock Wired (option)
zz
HOME LEAVE operation
ECONO operation
Indoor unit ON/OFF button
Signal receiving sign
z
2
3
z
2
3
R/C with back light
z
1
z
1
Note:
z
: Available
: Not available
1: With wired remote controller
2: With wireless remote controller