Specifications
7
A BP unit is an innovative
development which allows Super
Multi Plus outdoor units to be
connected to a wide range of
different indoor unit types. A BP
unit has the ability to precisely
vary refrigerant volume to meet
the cooling requirements of
individual room spaces.
Optional REFNET joint:
KHRP26A22T
3 ports BPMKS967A3
2 ports BPMKS967A2
The REFNET joint both
reduces the amount of
work involved in
installation and
increases the reliability
of the system.
Total main piping length
Total branch piping length
Total main and branch piping length
55 m
90 m
145 m
(55 + 90)
BP unit REFNET joint
A maximum total piping length of 145 m offers flexibility in the choice of
installation positions for the indoor units, and greatly simplifies system
planning.
The Super Multi PLUS E Series is connectable to up to 9 indoor units. While the BP unit and the REFNET
joint make installation simple, long piping length and simplified wiring broaden design flexibility.
Design flexibility and easy installation
Design flexibility and easy installation
Thin refrigerant piping makes handling and connecting easier, resulting in significantly reduced installation time.
As many as 9 indoor units can be connected to a single outdoor unit
Long refrigerant piping
Piping length for RMK(X)S160E
Note: Refrigerant charge is required. (Chargeless piping length 0 m)
>> 8 indoor units for a 14 kW installation >> 6 indoor units for a 11.2 kW installation
30 m
Max. height
difference
Main piping
BP unit
BP unit
Branch piping
Branch piping
For outdoor unit 15.5 kW installation
units
9
1
2
3
4
5
6
7
8