Specifications
5
The Super Multi PLUS E series outdoor units use the latest technologies to realise energy
saving performance and quiet operation.
Energy efficiency and quiet operation
Energy efficiency and quiet operation
RMXS160E
Master bedroom 3.5 kW class
Bedroom (1) 2.0 kW class
Bedroom (2) 2.5 kW class
Cooling operation
Heating operation
Power consumption 2,040 W
COP 3.82
Power consumption 2,620 W
COP 3.55
High Energy Savings
During night time
With DC inverter power control the air
conditioner can operate at low capacity
most of the time. This is especially
important at night in a residential situation
when the whole family is at home. DC
inverter power control is able to achieve a
high COP even when multiple indoor units
operate simultaneously for long periods of
time.
Quiet operation features that achieve total comfort
Quietness is yet another important feature of Daikin’s Super Multi PLUS E series. To
reduce sound and realise comfortable operation, latest technologies and features are
applied to the outdoor units, achieving the quiet operating sound level of 43 dB (A) in
night quiet mode.
Night quiet mode
Set on the outdoor PCB. Time of maximum
temperature is memorised. The low operating mode
will become active 8 hours*
1
after the peak
temperature in the daytime, and operation will return
to normal 10 hours*
2
after that. The operation sound
level for the night mode can be selected from 49 dB
(A) (Step 1), 46 dB (A) (Step 2) and 43 dB (A) (Step
3).
Automatic mode
Mode 1.
Automatic mode
Mode 1.
Starting time and ending time can be input. (External
control adaptor for outdoor unit, DTA104A61 or
DTA104A62, and a subsequently obtained timer are
necessary.)
Manual mode
Mode 2.
Combination of mode 1 and 2 can be used depending
on your needs.
Combined mode
Mode 3.
*1. Initial setting. Can be selected from 6, 8 and 10 hours.
*2. Initial setting. Can be selected from 8, 9 and 10 hours.
Notes: • This function is available in setting at site.
• The relationship of outdoor temperature (load) and time shown in the
graph is just an example.
Peak in the outdoor temperature
Capacity %
8 hrs 10 hrs
Operation sound dB (A)
49
8:00 12:00 16:00 20:00 0:00 4:00 8:00
50
100
52
0
Load %
Night mode
Night mode
ends
ends
Night mode
Night mode
starts
starts
Night mode endsNight mode starts
Night Mode
46
43
(Initial setting)(Initial setting)
Step 1 max. - 3dB (A)
(11.2 kW)
Step 2 max. - 6dB (A)
(11.2 kW)
Step 3 max. - 9dB (A)
(11.2 kW)
Step 1: 49 dB (A)
Step 2: 46 dB (A)
Step 3: 43 dB (A)
Operation sound level selectable
from 3 steps for the night mode
The capacity reduction rate differs depending on the operation sound level
step selected.