Service manual
Outdoor Unit Si18-201
322 Removal Procedure
4. Disconnecting the
compressor leads
"
Handle the sound insulation
with enough care. It may
damage the pipes around.
1
Undo the noise
insulation fixture string.
2
Pull up the noise
insulation.
3
Open up the terminal
cover noise insulation.
4
Detach the terminal
cover.
5
Disconnect the
compressor leads from
their terminals.
Step Procedure Points