Service manual
SiBE07-724_B Functions
List of Functions 3
Category Functions
FDKS25/35EAVMB
RKS25/35E2V1B
FDKS25/35EAVMB
RKS25/35G2V1B
Category Functions
FDKS25/35EAVMB
RKS25/35E2V1B
FDKS25/35EAVMB
RKS25/35G2V1B
Basic
Function
Inverter (with Inverter Power Control) {{Health &
Clean
Air-Purifying Filter — —
Operation Limit for Cooling (°CDB)
–10
~46
★
–10
~46
★
Photocatalytic Deodorizing Filter — —
Operation Limit for Heating (°CWB) — —
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control
{{
Standby Electricity Saving —
{
Titanium Apatite Photocatalytic
Air-Purifying Filter
——
Compressor Oval Scroll Compressor — —
Swing Compressor
{{
Air Filter (Prefilter)
{{
Rotary Compressor — — Wipe-Clean Flat Panel — —
Reluctance DC Motor
{{
Washable Grille — —
Comfortable
Airflow
Power-Airflow Flap — — MOLD PROOF Operation — —
Power-Airflow Dual Flaps — — Good-Sleep Cooling Operation — —
Power-Airflow Diffuser — — Timer WEEKLY TIMER Operation — —
Wide-Angle Louvers — — 24-Hour ON/OFF TIMER
{{
Vertical Auto-Swing (Up and Down) — — NIGHT SET Mode
{{
Horizontal Auto-Swing (Right and Left) — — Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{{
3-D Airflow — — Self-Diagnosis (Digital, LED) Display
{{
Comfort
Control
Auto Fan Speed
{{
Wiring Error Check Function — —
Indoor Unit Quiet Operation
{{
Anti-Corrosion Treatment of Outdoor
Heat Exchanger
{{
NIGHT QUIET Mode (Automatic) — —
OUTDOOR UNIT QUIET Operation
(Manual)
{{
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
{{
INTELLIGENT EYE Operation — — Flexible Voltage Correspondence — —
Quick Warming Function
(Preheating Operation)
——
High Ceiling Application — —
Chargeless 10 m 10 m
Hot-Start Function — — Either Side Drain (Right or Left) — —
Automatic Defrosting — — Power Selection — —
Operation Automatic Operation — — Remote
Control
5-Rooms Centralized Controller
(Option)
{{
Program Dry Operation
{{
Fan Only
{{
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
{{
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Remote Control Adaptor
(Normal Open Contact) (Option)
{{
Inverter POWERFUL Operation
{{
Priority-Room Setting — — DIII-NET Compatible (Adaptor) (Option)
{{
COOL / HEAT Mode Lock — — Remote
Controller
Wireless
{{
HOME LEAVE Operation
{{
Wired (Option)
{{
ECONO Operation — —
Indoor Unit ON/OFF Button
{{
Signal Receiving Sign
{{
R/C with Back Light — —
Temperature Display — —
Note:
{
: Holding Functions
— : No Functions
★
: Lower limit can be extended to –15°C by cutting
jumper. (facility use only)