Specifications

Heat Pump SiBE12-519
18 Specifications
2.2 Outdoor Units
Note:
1. See “Combination Capacity”.
2. The data are based on the conditions shows in the table below.
50Hz 230V
Model
2MXS40DVMB
Cooling Heating
Cooling Capacity
kW
Power Consumption
W—
Running Current
A—
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 1YC23GXD
Motor Output W 600
Refrigerant
Oil
Model FVC50K
Charge L 0.40
Refrigerant
Type R410A
Charge kg 1.20
Air Flow Rate
/min
HH 39 35
H35 32
L30 27
cfm
HH 1377 1236
H 1236 1130
L 1059 953
Fan
Type Propeller
Motor Output W 50
Starting Current A 6.2
Dimension (H
×
W
×
D) mm 640
×
685
×
285
Packaged Dimension (H
×
W
×
D) mm 676
×
800
×
366
Weight kg 39
Gross Weight kg 42
Operation
Sound
Sound Pressure
dBA 47 48
Silent Mode
dBA 43 44
Sound Power dBA 62
Piping
Connection
Liquid mm
φ
6.4
×
2
Gas mm
φ
9.5
×
2
Drain mm
φ
18
Heat Insulation Both Liquid & Gas Pipes
No. of Wiring Connection 3 for Power Supply, 4 for Interunit Wiring
Max. Piping Length m
30 (for Total of Each Room)
20 (for One Room)
Min. Piping Length m 1.5 (for One Room)
Amount of Additional Charge g/m 20 (20m or more)
Max. Installation Height Difference m
15 (between Indoor Unit and Outdoor Unit)
7.5 (between Indoor Units)
Drawing No. 3D049738#1
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/mi35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m