Service manual

SiENBE12-522A Instruction
System Configuration 139
Outdoor Unit
Indoor Unit
1. Louvres (vertical blades):
The louvres are inside of the air outlet.
2. Air outlet
3. Flap (horizontal blade)
4. Grille tab
5. Air inlet
6. Display
7. Air filter
8. Photocatalytic deodorizing filter or
Air purifying filter:
These filters are attached to the inside of the air
filters.
9. Front grille
10. Operation lamp (green)
11. TIMER lamp (yellow)
12. HOME LEAVE lamp (red):
Lights up when you use HOME LEAVE
Operation.
13. Indoor unit ON/OFF switch
Push this switch once to start operation.
Push once again to stop it.
The operation mode refers to the following
table.
Push the switch using an object with a sharp
tip, such as a pen.
This switch is useful when the remote controller
is missing.
14. Signal receiver:
It receives signals from the remote controller.
When the unit receives a signal, you will hear a
short beep.
Operation start .............beep-beep
Settings changed..........beep
Operation stop ..............beeeeep
Outdoor Unit
15. Air inlet:
(Back and side)
16. Air outlet
17. Refrigerant piping and inter-unit cable
18. Drain hose
19. Earth terminal:
It is inside of this cover.
Appearance of the outdoor unit may differ from some models.
17
18
19
16
15
Mode
Temperature
setting
Air flow
rate
FLKS COOL
22
°
C
AUTO
FLXS AUTO
25
°
C
AUTO