Specifications

EDUS281104 Installation of outdoor unit
Installation of indoor / outdoor unit 155
3P281953-2A
5 English
40 or more
Branch switch
and overcurrent
protective device
Indoor remote
controller
60 or more
60 or more
40 or more
Branch switch
and overcurrent
protective device
60 or more
Indoor unit
(in.)
DANGER
Do not install unit in an area where fl ammable materials are
present due to risk of explosion resulting in serious injury or
death.
Refrigerant is heavier than air and replaces oxygen. A
massive leak could lead to oxygen depletion , especially in
basements, and an asphyxiation hazard could occur leading
to serious injury or death.
Installation place (unit: inch)
Cautions on continuous installation
The connection piping outlet direction in the continuous
installation shown in the fi gures below is frontward or down-
ward.
When routing the piping rearward, secure space of 10 in. or
more on the right side of the outdoor unit. (The unit of nu-
meric values below is “inch”.)
Make some space for wiring with conduit and servicing
between the units.
(A) When an obstruction is present on the air inlet side
When the upward area is open
When one outdoor unit is installed individually(1)
When an obstruction is present only on the air inlet
side
4 or more
When an obstruction is present on the both sides
4 or more
4 or more
4 or more
When two or more outdoor units are installed side (2)
by side
When an obstruction is present on the both sides
40 or more
12 or more
8 or more
When an obstruction is present also in the upward area
When one outdoor unit is installed individually(1)
When an obstruction is present also on the air inlet
side
20 or less
40 or more
4 or more
When an obstruction is present also on the air inlet
side and both sides
6 or more
6 or more
20 or less
6 or more
40 or more
When two or more outdoor units are installed side (2)
by side
When an obstruction is present also on the air inlet
side and both sides
20 or less
8 or more
40 or more
12 or more
40 or more