Specifications

33
1-phase, 220-240 V/220 V, 50/60 Hz
BPMKS967B2BBPMKS967B3B
MODEL
Power supply
3 (connectable to 1-3 indoor units) 2 (connectable to 1-2 indoor units)
Number of ports
0.05
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (BP-indoor unit)
Number of wiring connections
ø9.5
X
1
ø19.1
X
1
Liquid
Gas
mm
mm
mm
mm
Piping
connections
(Brazing)
Both liquid and gas pipesHeat insulation
2.5 kW class to 7.1 kW class residential indoor unitsConnectable indoor units
Running current A
2.5
Min. rated capacity of
connectable indoor units
kW
180
X
294 (+356*)
X
350
Dimensions (H
X
W
X
D)
mm
8
Machine weight
kg
10
Power consumption
W
Note: * Total auxiliary piping length.
7.5
Max. rated capacity of
connectable indoor units
kW 20.8 14.2
ø6.4
X
3 ø6.4
X
2
ø15.9
X
3 ø15.9
X
2
Main
Branch
Main
Branch
Specifications
BP units for connection to residential indoor units
• A BP unit is an innovative development which allows VRVIII single outdoor unit series to be connected to
residential indoor units.
• A BP unit has the ability to precisely vary refrigerant volume to meet the cooling requirements of individual room
spaces.
• A BP unit is easy to disassemble, making repairing and recycling simple.
for connection to
residential indoor units
BP Units