Specifications

25
Ceiling Mounted Cassette Corner Type
Ceiling Mounted Cassette (Double Flow) Type
FXKQ25MAVE
2.9
9,900
2,500
Galvanised steel plate
11/9
FXKQ32MAVE
3.7
12,600
3,200
FXKQ40MAVE
4.7
16,000
4,000
FXKQ63MAVE
7.3
2.8 3.6 4.5
7.1
24,900
6,300
11/9 13/10 18/15
388/318 388/318 459/353 635/530
215
X
1,110
X
710
31.0
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYK45FJW1
White (10Y9/0.5)
70
X
1,240
X
800
8.5
215
X
1,110
X
710
31.0
6.4
12.7
70
X
1,240
X
800
8.5
215
X
1,110
X
710
31.0
6.4
12.7
70
X
1,240
X
800
8.5
215
X
1,310
X
710
34.0
9.5
15.9
BYK71FJW1
70
X
1,440
X
800
9.5
38/33 38/33 40/34 42/37
40/35 40/35 42/36 44/39
1-phase, 220-240 V/220 V, 50/60 Hz
Airflow rate (H/L)
m
3
/min
cfm
Sound level (H/L)
dB(A)
220 V
240 V
0.066 0.066 0.076 0.105
kW
(*1)
Btu/h(*1)
kcal/h(*1)
(*2)
Power supply
Cooling capacity
MODEL
Casing
Power consumption kW
Dimensions (H
X
W
X
D) mm
Machine weight kg
Piping
connections
Drain
Panel
(Option)
Model
Colour
mm
kg
Dimensions (H
X
W
X
D)
Liquid (Flare)
Gas (Flare)
mm
Weight
Galvanised steel plate
7/5
247/177
32/27
305
X
775
X
600
26.0
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYBC32G-W1
White (10Y9/0.5)
53
X
1,030
X
680
8.0
9/6.5
318/230
34/28
305
X
775
X
600
26.0
6.4
12.7
53
X
1,030
X
680
8.0
9/6.5
318/230
34/28
305
X
775
X
600
26.0
6.4
12.7
53
X
1,030
X
680
8.0
12/9
424/318
34/29
305
X
990
X
600
31.0
6.4
12.7
BYBC50G-W1
53
X
1,245
X
680
8.5
12/9
424/318
34/29
305
X
990
X
600
32.0
6.4
12.7
53
X
1,245
X
680
8.5
16.5/13
582/459
37/32
305
X
1,175
X
600
35.0
9.5
15.9
BYBC63G-W1
53
X
1,430
X
680
9.5
26/21
918/741
39/34
305
X
1,665
X
600
47.0
9.5
15.9
BYBC125G-W1
53
X
1,920
X
680
12.0
33/25
1,165/883
44/38
34/29 36/30 36/30 37/32 37/32 39/34 41/36 46/40
305
X
1,665
X
600
48.0
9.5
15.9
53
X
1,920
X
680
12.0
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE
FXCQ125MVE
2.3
7,800
2,000
2.9
9,900
2,500
3.7
12,600
3,200
4.7
16,000
4,000
5.8
19,800
5,000
7.3
24,900
6,300
9.3
31,700
8,000
14.5
2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
49,500
12,500
1-phase, 220-240 V/220 V, 50/60 Hz
0.077 0.092 0.092 0.130 0.130 0.161 0.209 0.256
Casing
Airflow rate (H/L)
m
3
/min
Sound level (H/L)
220 V
240 V
dB(A)
cfm
Power consumption kW
MODEL
Cooling capacity
kW
(*1)
(*2)
Btu/h(*1)
kcal/h(*1)
Power supply
Dimensions (H
X
W
X
D) mm
Machine weight kg
Piping
connections
Drain
Panel
(Option)
Model
Colour
mm
Dimensions (H
X
W
X
D)
Weight kg
Liquid (Flare)
Gas (Flare)
mm
Note: Specifications are based on the following conditions;
Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35°CDB. (*2) Indoor temp. of 27°CDB, 19°CWB, and outdoor temp. of 35°CDB.
Equivalent piping length: 7.5 m •Level difference: 0 m
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Specifications