User`s manual

25B8
29.5 24.5
35B8
32 25
109
Heat pump
BRC7E530W7
Cooling only
BRC7E531W7
A signal receiver must be added to the indoor unit.
Wireless remote controller and signal
receiver unit are sold as a set.
Wireless LCD remote controller
Signal receiver unit
(Installed type)
Compact
Sized to fit inside 600mm wide
ceiling grids
Two selectable temperature-sensors
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Designed for low draft
performance"
Consistent comfort throughout
Quiet operation has been achieved by a
compact body and newly developed spiral hub
cover that reduces the airflow resistance inside the
indoor unit.
Both indoor unit and wired remote controller (option) contain temperature-
sensors. Temperature sensing can be set at the unit or, to further improve
comfort level, closer to the target area at the wired remote control.
This feature must be set during commissioning by the technicians.
High setting provides maximum reach while low setting minimizes drafts.
Switchable fan speed: High/Low
Drain pump is equipped
as standard accessory
with 750 mm lift.
Uncomfortable cold air draft is avoided when heating operation starts
or when switching to heat after defrosting.
Hot start (after defrost)
Cooling only
Mould
prevention
Comfort Work & Servicing Control features OthersOption
Feature
Features
Model
Note: Remote controller cable not
included. Cables must be
procured locally.
Wired LCD remote controller
with weekly schedule timer
BRC1D61
Accessory required for indoor unit
Option
Heat pump
*
1
Applicable when wired remote controller is used
COMPACT MULTI FLOW
CEILING MOUNTED
CASSETTE TYPE
Comfortable
Quiet
Quiet, small-diameter fan
Multi-Flow System Blow direction can be
selected according to
installation.
1 pattern
4-way blow
4 pattern
3-way blow
2 pattern
2-way blow
" " denotes piping direction. Drain piping
" " denotes sealing member for air discharge
outlet (option) .
Note: For 3-way or 2-way blow installation, the sealing
member for air discharge outlet (option) must
be used to close off the unused outlet(s).
Note: Operation noise increases
when using 2-way or 3-way
blow.
Swing pattern selection
Draft prevention function
Switchable fan speed
Auto swing
Programme "Dry"
Hot start
Year-round cooling
applicable
Timer selector
Drain water lift-up
mechanism
Pre charged for
up to 10 m
Long-life filter
Mould-resistant treatment
for filter
Filter sign
Emergency operation
Self-diagnosis function
Fresh air intake kit
Control by 2 remote
controllers
Auto-cooling/heating
change-over
Auto-restart
Control by 1 remote
controller
External command
control
Central remote control
Interlock control
PE fin
Two selectable
thermo-sensors
Spiral hub cover
750 mm
Settable to 5 different levels
between
0° and 35°
Settable to 5 different levels
between 0° and 60°
Settable to 5 different levels
between 25° and 60°
Auto-swing
between 0° and 35°
Auto-swing
between 0° and 60°
Auto-swing
between 25° and 60°
Draft
prevention
setting
(Set on site)
(Set on site)
Standard
setting
Setting to
prevent
soiling of
ceiling
Auto-swing operation
distributes conditioned air
more evenly.
Air blow angle can be
adjusted in accordance with
room conditions.
AUTO-SWING
0°
0°
0°
25°
60°
60°
0°
35°
25°
60°
35°
60°
5 direction
Horizontal Blow
0°
0°
Less draft
can be felt
575 mm
575 mm
700 mm
700 mm
286
mm
50B8
36 27
High Low
60B8
41 32
Fits without the
need to cut T-bar
grid
T bar
600 mm
600 mm
Decoration
panel is also
compact.
Note: This angle above is provided as a guide. It may differ depending on the installation site.
Ceiling panel
Indoor unit
The switch box is built in to the
unit, so maintenance is possible
by simply removing the grill. An
inspection opening is not
required even for modules other
than 600 x 600.
FFQ25B8/35B8/50B8/60B8
Heat pump / Cooling only
*1
*1
••
••
Note : Anechoic chamber conversion value, measured according to JIS
parameters and criteria. During operation these values are somewhat higher
owing to ambient conditions.
dB(A)