User`s manual

4
3
Non-inverter
Inverter
Time
Running
current
Starting current
Time
Running current
CurrentCurrent
At startup, inverter raises frequency smoothly,
eliminating the starting current spike.
Soft starter is
unnecessary, making
electrical installation
work much simpler.
At startup, full power is used to achieve the set temperature
quickly. Then, the capacity is adjusted according to the outdoor
temperature changes and subtle indoor load changes to
achieve fine capacity control resulting in a more stable room
temperature.
Reduced installation work thanks to light, compact
outdoor unit.
Inverter performs variable control of frequency,
which determines air conditioner’s power
performance.
Full 360˚ airflow with improved
temperature distribution.
Enhanced comfort with Inverter
Small temp.
difference
Cools a room
in less time
Cooling operation
Inverter power control
Non-inverter type air conditioner
Time
Temp
Set temp
Non-inverter type air conditioners must be switched on
and off repeatedly, causing large fluctuations
of the room temperature.
Comfortable airflow
Comfortable
Round Flow cassette
Comfortable
Round Flow cassette
48
50
49
47
49
45
RZQ71F
Sound level
3
(dB(A))
RZQ100F
RZQ100K
50 45
RZQ125K
50 46
RZQ160K
Rated
4
Night Quiet Mode
Comparison of outdoor units
Conventional
NEW
100/125/160
1,345 mm
(RZQ100P-160P)
Height
125 kg
Weight
1,170 mm
98 kg
(RZQ100K-160K)
RZQ100K-160K
CompactCompact
Energy savingEnergy saving
Optimised Efficiency.
COP is equal to capacity (kW) divided by power consumption (kW),
and the larger the COP value, the higher the energy efficiency,
enabling cooling and heating with less electricity and increasing the
energy saving performance.
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp.,
27°CDB, 19.0°CWB; outdoor temp. 35°CDB Equiv. refrigeration piping, 7.5 m
(horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp.,
20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m
(horizontal)
What is COP (Coefficient of Performance)
COP
1
2
3
4
FCQ100KVEA FCQ125KVEA FCQ140KVEA
2.83
3.33
3.70
3.66
3.40
3.32
Full 360° airflow
delivery ensures uniform
airflow distribution.
4-way flow leaves areas
that cannot be covered.
Greater comfort
Improved energy saving
Round-Flow type
Conventional
4-way flow type
RZQ100P-160P
Compact and lightweight
Quiet operationQuiet operation
Nighttime quiet operation function
1,170
mm
175 mm
Reduced by
27 kg
Reduced
by
Cooling
1
Cooling
1
Cooling
1
Heating
2
Heating
2
Heating
2
NEW
NEW
Complies with MEPSComplies with MEPS
ROUND FLOWROUND FLOW
Note :
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
4
Value when cooling. Value will differ when heating.