DIMENSIONS
CEILING MOUNTED CASSETTE TYPE
(Unit: mm)
950
950
arrow viewA
Pipe Connection
Side
Drain Connection
Side
Note 2
8
6
7
860~910(Ceiling opening space) (Note 4)
710(Suspension position)
420
420
780(Suspension position)
860~910(Ceiling opening space) (Note 4)
300
or less
9
B
C
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Power-source wiring and a unit wiring connection
Connection wiring / remote control wiring connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)
1
2
3
4
5
6
7
8
9
1500mm or more
200mm or more
1500mm or more
When the blow-off grille is closing.
The required space is 500mm or more.
When uniting and closing a corner part
(both right and left of the blow-off grille to close),
it is 200mm or more.
1500mm
or more
1500mm
or more
200mm
or more
Required space
(round shape type)
840
340
80 80
B
55 55
E
D
C
95
40
29
850
175
Adjustable(0~675)
10
A
160
50
165
125
Connection position
of branch duct
(square-shaped type)
4 1 2
2 100
=
200
16-M4 Prepared hole
Connection position
of branch duct
Suspension bolt
4-M8~M10
C/L
20
157
350
280
330
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less
between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.
5
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
1500 or more
(required space)
From the floor side 2500 or more
Connection position
of branch duct
(square-shaped type)
Connection position
of branch duct
(round shape type)
20-M4 Prepared hole
35 or less
(Note 4)
35 or less
(Note 4)
A
For height installation
81
124
2x100=200
157
124
105
64
55
840
110
350
160
130
95
50
256
5
85
55
60
42
150
3
[FCQ71KVEA]
Connection position
of branch duct
(round shape type)
Connection position
of branch duct
(square-shaped type)
16-M4 Hole
arrow viewB
95
85
350
C/L
124
81
110
160
2x100=200
124
157
[FCQ71KVEA]
20-M4
Prepared hole
Connection position
of branch duct
(square-shaped type)
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
ø100
(knock
hole)
arrow viewC
2x100=200
160
C/L
350
124
95
109
80
90
183
25
90
157
80
213
124
[FCQ71KVEA]
C/L
160
167
67
95
29
93
90
196
8080
160
25
90
213
157
350
20-M4
Prepared hole
Connection position
of branch duct
(square-shaped type)
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
ø100
(knock
hole)
arrow viewC
2 100
=
200
[FCQ100-140KVEA]
1500 or more
(required space)
From the floor side 2500 or more
For height installation
50
64 160
256
157
350
130
95
60
105
150
42
9367
29160
167
840 5555
81 85
Connection position
of branch duct
(square-shaped type)
Connection position
of branch duct
(round shape type)
27-M4 Prepared hole
35 or less
35 or less
(Note 4)
(Note 4)
3
5
A
2 100
=
200
[FCQ100-140KVEA]
2 100
=
200
160
C/L
160
157
350
81 85
67
167
95
29
93
Connection position
of branch duct
(round shape type)
Connection position
of branch duct
(square-shaped type)
16-M4 Hole
arrow viewB
[FCQ100-140KVEA]
C
124
167
D
110
160
E
256
298
A
246
288
B
124
160
FCQ71KVEA
FCQ100-140KVEA
Indoor unit
Labor saving Overall energy savings
Simplified BMS
Multilingual (English, French, German,
Spanish, Italian, or Chinese)
Color LCD Touch panel Icon display
Yearly schedule
Power proportional distribution
* (option)
Auto cool/heat change-over
Temperature Limitation
* Limitations apply to some models and functions.
For details please contact your local sales office.
Necessary for optional interface adaptor for SkyAir series (DTA112BA51) with the Touch Controller.
Unification
adapter for
computerized
control
[DCS302A52]
Forced OFF
command from
fire alarm
monitoring panel
Pi Port
• Connection to power consumption meter
when using power proportional
distribution function. (Optional)
D NET Plus Adapter
(option) [DCS601A52]
Number of indoor unit expanded from 64 to 128.
Indoor Unit
RS-232C
Unified ON/OFF
and status
monitoring from
the central
monitoring panel
• CSV output of
power propor-
tional distribution
results
(Optional)
PCMCIA
Flash
Memory
Remote monitor-
ing and control
Trouble reports
Mobile Phone
Trouble
reports
Forced OFF
contact input
Special
Function
2
Special
Function
3
Special
Function
1
D -NET
HRV
Special
Function
4
Special
Function
3
Special
Function
1
DCS601C51
Doubling of number of connectable indoor
unit by adding a D -NET PLUS adapter
(Optional)
Special
Function
2
Support for centralized control from else
where., using a PC with a Web browser
(Optional)
Special
Function
3
Sending of e-mail alerts to a specified
address when malfunctions occur
(Optional)
Special
Function
4
Special
Function
5
Built-in Ethernet port for connecting to
the Internet or an intranet
Simple interlock function
New communication functions in the user-friendly icon based
multilingual controller simplity centralized control of the system
OPTIONS
Kit name
Heat pump
Air direction adjustment grille
Drain plug
Air direction adjustment grille
Drain plug One set includes 5 pieces for 5 units
One set includes 5 pieces for 5 units
Name of option Remark
RXS25EVMA RXS35EVMA RXS50FVMA RXS60FVMA
KPW945A4KPW937A4
KKP937A4
Kit name
Cooling only
Name of option Remark
RKS25EVMA RKS35EVMA RKS50FVMA RKS60FVMA
Outdoor unit
KPW945A4KPW937A4
KKP937A4
Kit name
KKPJ5F180
K-KYZP15C
KPT-60B160
KRP58M51
Heat pump
RZQ71FV4A RZQ100FV4A RZQ100KV4A RZQ125KV4A RZQ160KV4A
Central drain plug
Wire fixture for preventing overturning
Name of option
Fixture for preventing overturning
Demand adaptor