User`s manual

LCD REMOTE CONTROLLER
Wired remote controller has
built-in thermo-sensor
(Applies to wired remote controllers)
Enables temperature detection closer to target
area for improved comfort. (When using remote
control from another room, thermo-sensor in
indoor unit's air inlet must be selected.)
Non-polar, double-core connection
specifications simplify wiring
Non-polar, double-core remote controller wire
prevents wiring mistakes. Signal receiver unit (or
decoration panel) of wireless type is also easy to
connect.
Facilitates maintenance and repair
All initial settings can be set from the remote
controller. After interior construction is complete,
ceiling mounted cassette type can be remotely
set without having to use stepladder access for
manual setting.
Setting contents: High ceiling use, air direction, filter type, address
for centralised control (group control address is set automatically).
Remote controller is equipped with model name
and failure display functions. This facilitates
service in the unlikely event of a malfunction.
SkyAir shares common control with
HRV (heat reclaim ventilation) and
the other Daikin air-conditioning
units, thus simplifying interlocking
operations.
Easily adaptable to large-scale, high-function,
centralised remote control systems.
Installing and connecting control wiring between
SkyAir and other Daikin air-conditioning
equipment is easy.
Optional adaptor for external commands or
remote control of external equipment has been
standardised to one type.
Central remote controller
Interface adaptor for SkyAir series
Easily adaptable to large-scale, high-function, centralised remote control system.
Centralised control, with setting as
simple as it is with a standard
remote controller, of up to 64 groups
(1,024 indoor units) is possible.
DCS302CA61 (Option)
DTA112BA51 (Option)
With its high functionality, the full
colour “all-in-one” graphic controller
facilitates management of SkyAir
System in a variety of ways.
DCS601C51 (Option)
Unified on/off controller
Centralised control of on/off by
group or all at once for up to 256
indoor units.
DCS301BA61 (Option)
Schedule timer
Unified control of weekly schedule
for up to 1,024 indoor units.
DST301BA61 (Option)
Schedule timer sets on/off time in 1 minute units
to be executed twice a day for a week at a time.
*Please refer to the page 29 for the details.
LCD REMOTE CONTROLLER
Easy-to-read LCD remote controller allows
various system control configurations and
can control multiple indoor units.
LCD panel shows operating status in letters, numbers, and motion.
Airflow / swing display
Displays auto-swing operating status and setting position of air discharge angle.
Preset temperature / operation mode display
Displays preset room temperature and operating status (fan, dry, cool).
Programming time display
Operation start and stop time can be set for individual timers up to 72 hours. The liquid crystal display also shows
when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
Simple system provides a diverse assortment of control modes.
Control by 1
remote controller
Control pattern Wired remote controller Wireless remote controller
Control by 2
remote controllers
Group control
Control by
external command
Centralised remote
control
Interlock control
with HRV
(Basic system)
Link by remote
controller group control.
Zone link control by
centralised control.
For control from 2
locations such as in
room and control room,
exits, etc.
For simultaneous
control of up to 16
indoor units.
Centralised control of
up to 64 indoor units
from remote location
up to 1 kilometer away.
Control by 1 wireless remote
controller and 1 wired remote
controller (See note 1)
Signal receiver unit installed
on indoor unit
Signal receiver unit installed
on indoor unit
HRV for indoor units within a zone are operated by interlocking
Can also be operated independently by remote controller.
Central remote controller (option)
HRV
Can be operated simultaneously
or independently by remote controller
(set by ventilation mode)
HRV
Central remote controller (option)
Non-polar, double-core
(max. wiring length 500 m)
Connects 2 wired
remote controllers
Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Optional wiring adaptor for
electrical appendices is necessary
Central remote controller (option)
Can be operated simultaneously
by remote controller
(set by ventilation mode)
HRV
HRV for indoor units within a zone are operated
by interlocking
Central remote controller (option)
HRV
Operation and
surveillance is carried out
using the contact signal
from the operation control
box in the building
surveillance (security)
room.
Optional wiring adaptor for
electrical appendices is necessary
Remote controller options are shown on the page introducing each indoor unit model.
Necessary optional accessory
Indoor units applicable for the remote controller
Signal receiver unit is contained inside decoration panel or indoor unit
CEILING MOUNTED CASSETTE TYPE
WALL MOUNTED TYPE
COMPACT MULTI FLOW TYPE
BRC7E531W
BRC7F632F
CEILING MOUNTED BUILT-IN TYPE
BRC4C62
Standard accessory
CEILING MOUNTED SLIM DUCT TYPE
Cooling onlyHeat pump
BRC7C610W
BRC7E530W7
CEILING SUSPENDED TYPE
BRC7EA66BRC7EA63W
LCD wireless remote controller
Note: The signal receiver unit shown in the
photograph is for mounting inside
the decoration panel of the ceiling
mounted cassette type.
Wireless remote
controller
Light receptor mounted type
BRC7F632F
The wireless remote controller is
supplied in a set with a signal
receiver.
Shape of signal receiver unit
differs according to the indoor
unit.
Signal receiver unit
(For ceiling mounted
cassette type)
Remote control is equipped with weekly timer function.
Wired LCD remote controller with weekly schedule timer
BRC1D61
24-hour clock function (1-hour backup for
power failures)
Programming function for each day of week.
Scheduling possible of start/stop and
temperature limit (5 settings/day)
Programming can be enabled or disabled.
Copy function for programmed schedules.
20
19
Optional SkyAir series interface
adaptor required.
1
Optional SkyAir series interface
adaptor required.
1
Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.
1
The ceiling mounted cassette type come standard with an interface adaptor for SkyAir series (DTA112BA51).
Enables centralised control via connection
to a high-speed, DIII-NET communication
system, adopted for the Daikin VRV system.
Necessary for interface adaptor for SkyAir series with the
central remote control units shown at above.
The interface adaptor for the Skyair series is
optional except for the ceiling mounted cassette
type.