Service manual

ESIE04-01 Functional Diagrams
Part 1 – System Outline 1–67
3
1
4
5
Refrigerant pipe
size
P Pipe size down and pipe size up is available for main piping (L1) only.
P Not using the standard pipe size may result in capacity decrease. It is up to the installer to judge
on this phenomenon carefully in function of the complete installation.
Refrigerant pipe size
Gas pipe
Model Size-down Standard size Size-up
RZQ71B7V3B φ 12.7
φ 15.9
––
RZQ100 & 125B7V3B –– φ 19.1
Liquid pipe
Model Size-down Standard size Size-up
RZQ71~125B7V3B φ 6.4
φ 9.5 φ 12.7
RZQ - Final.book Page 67 Monday, September 20, 2004 11:24 AM