Installation manual
Installationshandbok
1
E(D/B)(H/L)Q011~016AA6V3+W1
Enhet för luft/vatten-värmepumpsystem
4PW51121-1A
INNEHÅLL Sida
Introduktion ....................................................................................... 1
Allmän information..................................................................................... 1
Den här handbokens omfattning................................................................ 2
Modellidentifiering...................................................................................... 2
Tillbehör ............................................................................................ 2
Tillbehör som medföljer enheten ............................................................... 2
Säkerhetsöverväganden ................................................................... 2
Före installation................................................................................. 3
Viktig information om det använda köldmedlet.................................. 3
Att välja plats för installationen.......................................................... 4
Välja en placering i kalla klimat ................................................................. 4
Säkerhetsåtgärder vid installation ..................................................... 4
Dränering................................................................................................... 5
Installationsmetod för att förhindra att enheten välter................................ 5
Utrymme för installation och service.......................................................... 5
Typexempel ....................................................................................... 6
Tillämpning 1 ............................................................................................. 6
Tillämpning 2 ............................................................................................. 6
Tillämpning 3 ............................................................................................. 7
Tillämpning 4 ............................................................................................. 7
Översikt över enheten ....................................................................... 8
Öppna enheten.......................................................................................... 8
Huvudkomponenter ................................................................................... 8
Vattenrördragning .................................................................................... 10
Påfyllningsvatten...................................................................................... 12
Rörisolering ............................................................................................. 12
Kabeldragning.......................................................................................... 12
Installation av den digitala styrenheten.................................................... 17
Start och konfiguration .................................................................... 18
Ställa in dipswitcharna, översikt............................................................... 18
Konfiguration av rumstermostatinstallationen.......................................... 18
Konfiguration av pumpdrift....................................................................... 19
Konfiguration av hushållsvarmvattenberedare......................................... 19
Första start vid låga utomhustemperaturer.............................................. 19
Kontroller före drift ................................................................................... 19
Sätta på enheten ..................................................................................... 20
Ställa in pumphastigheten ....................................................................... 20
Inställningar ............................................................................................. 20
Inställningar, tabell................................................................................... 26
Testkörning och slutkontroll............................................................. 28
Automatisk testkörning ............................................................................ 28
Testdrift (manuell) .................................................................................... 28
Slutgiltig kontroll....................................................................................... 28
Underhåll......................................................................................... 28
Felsökning....................................................................................... 29
Allmänna riktlinjer .................................................................................... 29
Allmänna symptom .................................................................................. 29
Felkoder................................................................................................... 30
Tekniska specifikationer .................................................................. 32
Allmänt..................................................................................................... 32
Elektriska specifikationer ......................................................................... 32
INTRODUKTION
Allmän information
Tack för att du köpte den här monoblock-AD-
utomhusenheten.
Enheterna är avsedda för både uppvärmnings- och kylnings-
tillämpningar. Enheterna kan kombineras med Daikin-
fläktkonvektorer, golvvärmeutrustning, lågtemperaturradiatorer,
Daikins hushållsvarmvattenberedare och solvärmepaketet för
hushållsvarmvattenberedning.
Enheter för uppvärmning/komfortkyla och endast uppvärmning
Sortimentet av monoblock-AD-utomhusenheter
består av två huvudversioner: En värme/kyla-version (EB) och en
version för enbart uppvärmning (ED).
Båda versionerna levereras med en integrerad reservvärmare för
ytterligare uppvärmningskapacitet vid låga utomhustemperaturer.
Reservvärmaren fungerar också som reserv vid driftsavbrott i och
som frysskydd för vattenrör utomhus under vintern. Den
fabriksinställda kapaciteten för reservvärmaren är 6 kW, men under
installationen kan reservvärmarens kapacitet begränsas till
3 kW/2 kW. Reservvärmarens kapacitet bygger på
jämviktstemperaturen för läget enligt nedan.
EDHQ011~016AA6V3 EDHQ011~016AA6W1
EDLQ011~016AA6V3 EDLQ011~016AA6W1
EBHQ011~016AA6V3 EBHQ011~016AA6W1
EBLQ011~016AA6V3 EBLQ011~016AA6W1
Enhet för luft/vatten-värmepumpsystem
Installationshandbok
LÄS DESSA INSTRUKTIONER NOGGRANT FÖRE
INSTALLATIONEN. SPARA MANUALEN PÅ LÄTTILL-
GÄNGLIG PLATS FÖR FRAMTIDA BRUK SOM
REFERENS.
FELAKTIG INSTALLATION ELLER ANSLUTNING AV
UTRUSTNING ELLER TILLBEHÖR KAN ORSAKA
ELEKTRISK CHOCK, KORTSLUTNING, LÄCKAGE,
BRAND ELLER ANNAN SKADA PÅ UTRUSTNINGEN.
ANVÄND ENDAST TILLBEHÖR FRÅN DAIKIN SOM ÄR
SPECIELLT TILLVERKADE FÖR ATT ANVÄNDAS MED
UTRUSTNINGEN OCH LÅT EN UTBILDAD
INSTALLATÖR INSTALLERA DEM.
OM DU HAR FRÅGOR ANGÅENDE INSTALLATIONS-
FÖRFARANDET ELLER ANVÄNDNINGEN TAR DU
KONTAKT MED NÄRMASTE DAIKIN-
ÅTERFÖRSÄLJARE FÖR RÅD OCH INFORMATION.
1 Värmepumpskapacitet
2 Nödvändig uppvärmningskapacitet (beroende på placering)
3 Ytterligare uppvärmningskapacitet med reservvärmare
4 Jämviktstemperatur (kan anges via användargränssnittet, se
"Inställningar" på sid 20)
T
A
Omgivningstemperatur (utomhus)
P
H
Uppvärmningskapacitet
T
A
4
3
1
2
P
H
1D_IM_4PW51121-1A.book Page 1 Tuesday, January 27, 2009 7:46 AM