2.18 MOLD SHOCK Operation
The room is kept clean by removing excessive moisture by rapidly lowering the humidity in the
room for 1 hour, and keeping operation for 2 hours (total 3 hours).
Operation It is not self-starting operation.
Refer to the operation manual for details.
Features
Dry shock method (Mold Shock Operation)
Method to prevent the generation of mold by suddenly drying the humid environment. It is
generally said that the growth of mold can be prevented by lowering the humidity to half and
continuing the operation for 3 hours.
Time chart
z
Operation runs about for 3 hours in rotal while charging colors of the multi-colored
indicator lamp.
z
Reheating dehumidifying which dehumidifies continuously.
MOLD SHOCK Opeation
(Hold down for 2 seconds.)
(R5975)
Mold before mold shock operation
Fewer molds grow as compared with
in the case without Mold Shock Operation.
Without mold shock operation
With mold shock operation
(R5107)
The test was conducted at DAIKIN’s lab with use of the mold
sensor of Environmental Biological Research Institute.
Operation
ON
<Air flow rate in reheating dehumidifying>
Indoor Unit Fan
Reheating dehumidifying
room temperature setting
Room Temperature
Air flow direction
<Angle in comfort air flow mode>
Compressor
Continuous operation in
max. frequency
Reheating dehumidifying
primary setting.
OFF
Approx. 3 hours
(R5108)
<Note> The room temperature becomes about 5˚C lower than the temperature at the start of operation.