Specifications
Main Functions SiBE04-624
42 Function and Control
Inside Drying
Exhausting Moisture
Switching air supply / exhausting
We have developed this function on a damper inside the humidification unit, by leaving
conventional air intake fan in place that supplies air from outdoor to indoor as it is.
Condition for operation
1. Accumulated operation time: 21,600 min. (approx.15 days)
2. Accumulated cooling/dehumidifying operation time: 5,400 min. (approx.15 days x 6 hours)
This function starts when both conditions are met.
Note
This is not the function for eliminating dust or mold attached inside the air conditioner.
During operation, smells may occur.
This function sometimes does not begin when outdoor temperature or indoor humidity is
extremely high.
Depending on the temperature conditions, moisture exhaustion function is not carried out.
1. Drained water discharge
Drained water in drain pan is discharged.
2. Inside drying operation
After the drained water discharged, the moisture etc.
which are left on drain pan or heat exchanger are dried
by evaporation.
3. Moisture exhaustion
Exhaust moisture to outdoors using the humidification hose.
Air supply position Exhaust position
To Outdoor
To Indoor
From Indoor
From Outdoor
(R3374)