Specifications
SiBE04-624 Main Functions
Function and Control 41
2.16 MOLD PROOF Operation
This is an integrated naming of functions such as inside drying, moist air exhaustion, mold-
prevention stick. Drying inside the air conditioner prevents mold or odors to be generated.
Operation Operation can be selected from automatic / manual.
Auto operation
(approximately once every 2 weeks)
If the unit is set to “MOLD PROOF ON”, the MOLD PROOF operation will start automatically
after the unit has been run is “SARARA” DRYING or COOLING mode, depending on the
amount of time the unit has been run (approximately once every 2 weeks.)
The default is set to “MOLD PROOF OFF”.
Manual operation
∗ Refer to the operation manual for details.
Features
Time chart
Operation runs about for 3 hours while changing colors of the multi-colored indicator lamp.
MOLD PROOF operation
(Hold down for 2 seconds.)
(R5974)
Indoor fan
Discharge
moisture
Horizontal flap
Pre-drying
10 min.
Drying by
heating 30 min.
Finish up drying
operation 80 min.
Thorough operation
60 min.
Discharge moisture
while heating and
drying the heat exchanger
Perfectly dry the inside by short
circuit blowing + discharge
Lower relative humidity and
inactivate fungi by short circuit
heating + discharge
Compressor
Fully opened damper
Exhaust side
Moisture discharge fan ON
OFF
Start
Complete
Cooling Stop
LLL tap
OFF
Minimum open
Fully closed
Heating Min.
OFF
3 hours
(R5973)