Specifications

SiBE04-624 Main Functions
Function and Control 39
2.12 Indoor Unit Quiet Operation
Features Forced dropping of the fan tap decreases the airflow rate and reduces airflow noise. (Noise is
reduced by about 3 dB as compared to that in L tap.)
Note
z
Airflow rate can not be set.
z
Since the performance is somewhat lowered as compared to that in normal operation
(70% under rated conditions), the room may not be cooled (or heated) when this operation
is used for a long time.
z
The indoor unit quiet operation is kept in memory even when the power supply is turned
OFF.
The indication remains on the display of the wireless remote controller and the indoor unit
quiet operation works when the power is turned ON again.
2.13 Multi-colored Indicator Lamp
Features Current operation mode is displayed in color of the lamp of the indoor unit which changes in 8
colors. Operating status can be monitored even in automatic operation in accordance with the
content of actual operation.
z
The lamp color changes according to the operation.
z
HEATING..................................................Red
z
“URURU” HUMIDIFYING /
HUMID HEATING .....................................Orange
z
COOLING .................................................Green
z
“SARARA” DRYING /
DRY COOLING.........................................Yellow
z
The lamp color also changes according to the optional function.
z
FLASH STREAMER AIR PURIFYING/
FRESH AIR SUPPLY VENTILATION.......White
(Only for the first 2 seconds during operation of the air conditioner.)
z
MOLD PROOF..................Purple & blue
Blue & light blue Light blue & white White
z
MOLD SHOCK..................Blue & light blue & white
(R5990)
Multi-colored indicator lamp