Specifications

SiBE04-624 Indoor Unit
Removal Procedure 245
1.9 Removal of the Connecting Duct
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1. Remove the connecting
duct for humidifying hose
Preparation
Remove the front grille
according to "Removal of
the Front Grille".
Since inside of the
connecting duct has
projection hooks, shake the
hose up and down to
remove.
Rotate in the same direction
as when assembling for
easy removal.
Put the drain hose at the
bottom and make an
inclination downward.
1
Detach the humidifying
hose from the duct unit.
2
Loosen the 1 fixing
screw for the duct unit.
3
Lift the right side to
undo the projections
and slide to the left.