Specifications
SiBE04-624 Indoor Unit
Removal Procedure 239
2. Remove the power supply
terminal board
1
Loosen the 1 screw
and pull out the
terminal board
sideward.
2
Disconnect the red
terminal with pliers and
black and white
terminals with a flat
screwdrivers on the
terminal board.
Black...... (1) Power supply
White ..... (2) Power supply
Red........ (3) Signal
3. Remove the control PCB
Clamps should be used all
the time.
Fix it as it was before.
1
Cut the 3 clamps.
2
Undo the earth wire
from the hook.
Step Procedure Points