Specifications

Troubleshooting SiBE04-624
156 Service Diagnosis
Troubleshooting
Clean the streamer unit.
Clean the streamer unit.
Install it surely.
Correct the connection.
Replace the limit switch.
Replace the harness.
Replace the streamer unit
PCB (A5P)
Note 1.
Be careful not to break the
electrode in cleaning.
Note 2.
Since the electrode part is
electrified in high voltage,
be sure to pull out the
power supply plug or turn
breaker off in cleaning the
electrode part. (Touching i
n
electrifying results in
electrical shock.)
(R6006)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Dust or drip of
water is on the streamer
unit.
YES
NO
NO
YES
Does the
multi-monitor LED blink about
1 minute after air purifying
operation starts.
NO
YES
Is the streamer unit
installed surely.
NO
YES
Turn off the power supply
(Turn off the breaker).
Check the connector connection
(S52).
* Connect the connector again for
ensuring the connection.
Check the harness.
Is it normal?
NO
YES
Is the limit switch normal?
YES
Is it broken?
NO