Specifications
Electric Characteristics ED01-505
20 Room Air Conditioners D-Series
11.Electric Characteristics
3D049939
3D049940
Power Supply COMP OFM IFM
Indoor Unit Outdoor Unit Hz-Volts Voltage Range MCA MFA LRA RLA W FLA W FLA
FT25DVM R25DV1
50-220
MAX. 50Hz 264V
MIN. 50Hz 198V
4.7
15
19 3.4
25 0.27 18 0.16
50-240 5.2 21 3.8
FT35DVM R35DV1
50-220
MAX. 50Hz 264V
MIN. 50Hz 198V
6.7
15
26 5.0
25 0.27 18 0.16
50-240 6.7 28 5.0
SYMBOLS: NOTES:
MCA : MIN. CIRCUIT AMPS (A) 1. RLA is based on the following conditions.
Indoor temp. 27°CDB/19°CWB
Outdoor temp. 35°CDB.
2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
MFA : MAX. FUSE AMPS (A)
LRA : LOCKED ROTOR AMPS (A)
RLA : RATED LOAD AMPS (A)
OFM : OUTDOOR FAN MOTOR
IFM : INDOOR FAN MOTOR
FLA : FULL LOAD AMPS (A)
W : FAN MOTOR RATED OUTPUT (W)