Installation manual
7 ■English
Indoor Unit Installation
3-2. Left-side, left-back, or left-bottom piping
How to replace the drain plug and drain hose
•Replacing onto the left side
1)Removetheinsulationxingscrewontheright
andremovethedrainhose.
2)Removethedrainplugontheleftsideand
attachittotherightside.
3)Insertthedrainhoseandtightenwithincluded
insulationxingscrew.
*(Forgettingtotightenthismaycausewater
leakages.)
Drain hose attachment position
* The drain hose is on the back of the unit.
Front side of unit
Attachment on the right side (factory default)
Attachment on the left side
Drain hose Drain hose
Insulation 
fixing screw
Insulation 
fixing screw
Right sideLeft side
1)Attachthedrainhosetotheundersideoftherefrigerantpipes
withadhesivevinyltape.
Remove pipe port cover here for left-bottom piping.
Remove pipe 
port cover 
here for left-
side piping.
Left-bottom piping
Left-side 
piping
Left-back 
piping
2)Besuretoconnectthedrainhosetothedrainportinplaceofa
drainplug.
How to set drain plug
No gap.
Do not apply lubricating 
oil (refrigeration oil) 
when inserting.
Application of causes 
deterioration and drain 
leakage of the plug.
Insert a hexagonal wrench (4mm).
3)Shapetherefrigerantpipealongthepipe
pathmarkingonthemountingplate.
4)Passdrainhoseandrefrigerantpipes
throughthewallhole,thensettheindoor
unitonmountingplatehooks,usingthe
markingsatthetopofindoorunitasa
guide.
5)Pullintheinter-unitwire.
6)Connecttheinter-unitpipes.
Drain 
hose
Caulk this hole 
with putty or 
caulking material.
Bind with adhesive 
vinyl tape.
 A 
Mounting plate
Wrap insulating tape around the 
bent portion of refrigerant pipe. 
Overlap at least half the width of 
the tape with each turn.
7)Wraptherefrigerantpipesanddrainhosetogetherwithinsulationtape
asrightgure,incaseofsettingthedrainhosethroughthebackofthe
indoorunit.
8)Whileexercisingcaresothattheinter-unitwiredonotcatchindoorunit,
pressthebottomedgeofindoorunitwithbothhandsuntilitisrmly
caughtbythemountingplatehooks.Secureindoorunittothemounting
platewithindoorunitxingscrews(M4×12L).
Refrigerant
pipes
Drain hose
Bottom frame
F Indoor unit fixing screw
  (M4 × 12L) (2 points)
Mounting
plate
A
Inter-unit wire
3-3. Wall embedded piping
Followtheinstructionsgivenunderleft-side,left-back,orleft-bottompiping.
1)Insertthedrainhosetothisdepthsoitwon’tbepulledoutofthedrain
pipe.
Inner wall
Vinyl chloride 
drain pipe 
(VP-30)
Drain hose50mm 
or more
Insert drain hose 
to this depth so 
it won’t be pulled 
out of drain pipe.
Outer wall
01_EN_3P297034-1.indd 7 10/12/2011 11:37:03 AM