■English 6
•Removethepipeportcoverasshownbelow.
1)Cutoffthepipeportcoverfrominsidethefrontgrilleusingacopping
saw.
Applythebladeofthecoppingsawtothenotch,andcutoffthepipe
portcoveralongtheslit.
2)Aftercuttingoffthepipeportcover,performling.Removetheburrs
alongthecutsectionusingahalfroundneedlele.
CAUTION
•Ifthepipeportcoveriscutoffusingnippers,thefrontgrillewillbedamaged.Pleasedonotusenippers.
•Wearglovesduringthepipeportcoverremoval.
3-1. Right-side, right-back, or right-bottom piping
1)Attachthedrainhosetotheundersideoftherefrigerantpipeswith
adhesivevinyltape.
2)Wraptherefrigerantpipesanddrainhosetogetherwithinsulation
tape.
Right-bottom 
piping
Right-back piping
Bind coolant pipe 
and drain hose 
together with 
insulating tape.
Remove pipe port cover 
here for right-side piping.
Remove pipe port cover 
here for right-bottom piping.
3)Passthedrainhoseandrefrigerantpipesthroughthewallhole,
thensettheindoorunitonthemountingplatehooksbyusingthe
markingsatthetopoftheindoorunitasaguide.
Mounting plate
A
4)Openthefrontpanel,thenopentheservicelid.
(Refertopreparationbeforeinstallation.)
5)Passtheinter-unitwirefromtheoutdoorunitthroughthe
feed-throughwallholeandthenthroughthebackoftheindoor
unit.Pullthemthroughthefrontside.Bendtheendsoftie
wiresupwardforeasierworkinadvance.(Iftheinter-unitwire
endsaretobestrippedrst,bundlewireendswithadhesive
tape.)
6)Pressthebottomframeoftheindoorunitwithbothhandsto
setitonthemountingplatehooks.Makesurethewiresdonot
catchontheedgeoftheindoorunit.
Wire guide
When stripping the 
ends of inter-unit wire 
in advance, bind right ends 
of wires with insulating tape.
Hang indoor unit’s hook here.
Inter-unit wire
Mounting plate
A