Specifications
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
43
Wide range
Energy saving
RXYQ34MY1B
RXYQ36MY1B
REYQ34MY1B
REYQ36MY1B
RXYQ38MY1B
RXYQ40MY1B
RXYQ42MY1B
REYQ38MY1B
REYQ40MY1B
REYQ42MY1B
RXYQ44MY1B
RXYQ46MY1B
RXYQ48MY1B
REYQ44MY1B
REYQ46MY1B
REYQ48MY1B
RXYQ5MY1B RXYQ8MY1B
RXYQ10MY1B
REYQ8MY1B
REYQ10MY1B
RXYQ12MY1B
RXYQ14MY1B
RXYQ16MY1B
REYQ12MY1B
REYQ14MY1B
REYQ16MY1B
RXYQ18MY1B
RXYQ20MY1B
REYQ18MY1B
REYQ20MY1B
RXYQ22MY1B
RXYQ24MY1B
RXYQ26MY1B
REYQ22MY1B
REYQ24MY1B
REYQ26MY1B
RXYQ28MY1B
RXYQ30MY1B
RXYQ32MY1B
REYQ28MY1B
REYQ30MY1B
REYQ32MY1B
34, 36 HP 38, 40, 42 HP 44, 46, 48 HP
5 HP 8, 10 HP 12, 14, 16 HP 18, 20 HP 22, 24, 26 HP 28, 30, 32 HP
Heat Pump Type
Heat RecoveryType
Value represents that to be achieved by a single outdoor unit.
The new VRV II is a significantly improved version of the original VRV, which revolutionized
building air conditioning. The latest in air conditioning technologies are applied to fulfill all the
needs of our customers. The VRV II opens the door to the future of air conditioning.
Wide range of indoor units
Highest COP
available during both cooling and heating operation
A maximum 48 HP with built-in flexibility
This level of power is a quantum leap over the previous 30 HP, taking Daikin into the top rank of the
industry. The number of modules has been standardized from nine to six and the number of casings from
four to three, streamlining the design process to offer enhanced flexibility.
2 HP increments
By providing a range of horse
power levels in 2 HP
increments*
1
, Daikin responds
exactly to customer needs.
*1. Except for 5 HP
Indoor units
A wide range of indoor units includes 10 types and 63 models, so the needs of all customers can be
precisely met.
Ceiling mounted cassette (Double flow)
Type
Capacity Range Capacity Range
20 (0.8 HP) 40 (1.6 HP) 63 (2.5 HP) 80 (3.2 HP) 100 (4 HP) 125 (5 HP) 200 (8 HP) 250 (10 HP)50 (2 HP)32 (1.25 HP)25 (1 HP)
Ceiling mounted cassette
(Multi flow) super cassette
Ceiling mounted cassette corner
Ceiling mounted built-in
Ceiling mounted duct
Ceiling suspended
Wall mounted
Floor standing
Concealed floor standing
600 x 600 multi flow ceiling mounted
cassette
FXCQ20MVE
FXSQ20MVE
FXAQ20MVE
FXLQ20MVE
FXNQ20MVE
FXZQ20MVE
FXCQ25MVE
FXFQ25MVE
FXKQ25MVE
FXSQ25MVE
FXAQ25MVE
FXLQ25MVE
FXNQ25MVE
FXZQ25MVE
FXCQ32MVE
FXFQ32MVE
FXKQ32MVE
FXSQ32MVE
FXHQ32MVE
FXAQ32MVE
FXLQ32MVE
FXNQ32MVE
FXZQ32MVE
FXCQ40MVE
FXFQ40MVE
FXKQ40MVE
FXSQ40MVE
FXMQ40MVE
FXAQ40MVE
FXLQ40MVE
FXNQ40MVE
FXZQ40MVE
FXCQ50MVE
FXFQ50MVE
FXSQ50MVE
FXMQ50MVE
FXAQ50MVE
FXLQ50MVE
FXNQ50MVE
FXZQ50MVE
FXCQ63MVE
FXFQ63MVE
FXKQ63MVE
FXSQ63MVE
FXMQ63MVE
FXHQ63MVE
FXAQ63MVE
FXLQ63MVE
FXNQ63MVE
FXCQ80MVE
FXFQ80MVE
FXSQ80MVE
FXMQ80MVE
FXFQ100MVE
FXSQ100MVE
FXMQ100MVE
FXHQ100MVE
FXCQ125MVE
FXFQ125MVE
FXSQ125MVE
FXMQ125MVE
FXMQ200MVE
FXMQ200MVE
Model
•
Refer to p.37 for combination details.
COP for
cooling operation
Top-class Energy Savings
RXYQ8MY1B
10 series, 63 models
RXYQ20MY1B
COP for
heating operation
RXYQ8MY1B
RXYQ20MY1B
What is COP?
COP (Coefficient of Performance) indicates energy consumption efficiency.
A higher COP means less electricity used, resulting in greater energy efficiency.
Power consumption (kW)
Capacity (kW)
COP=
: http://splitoff.ru/tehn-doc.html










