Specifications

21
Aero fitting grilleAero spiral fan
DC fan motor structure
These new features achieve a low noise fan with a large
airflow, and realize a compact casing together with the
compressor linking technology.
New shape promotes a
spiral discharge airflow,
resulting in reduced
pressure loss.
Bending of the fan
blade edge reduces
turbulence, resulting
in less pressure loss.
The new sub-cool feature prevents the flushing of
liquid refrigerant from long piping due to the effects
of SCe-bridge.
This can reduce the refrigerant volume required in
piping and thereby enable a reduction in piping size.
Aero fitting grille and aero spiral fan
Realizes a compact casing by stacking the Inverter and control
pcbs plus optimizing the internal design to suit airflow speed.
This achieves lower noise and reduces the power required by
the large-diameter fanned outdoor unit.
Compact aero box
SCe-bridge Circuit
Ferrite magnet
Secret to raising energy-efficiency! 
Powerful magnets
Neodymium magnet is much more powerful
than the widely used ferrite magnets.
Neodymium magnet
Scrolling
Reluctance
DC motor
Reluctance DC scroll compressor
By adoption of the Sine Wave which smoothes rotation of a motor,
operation efficiency has improved sharply.
Smooth sine wave DC Inverter
Sine Wave DC inverter
To optimize the path of heat exchanger.
e-Pass heat exchanger
High torque and efficiency is attained by employing neodymium magnets.
Achieves 70% reduction in volume.
Over heating gas
Over heating gas
Influence smallness
of overheating gas
A heating region and a super 
cooling region are separated.
• First use across entire range of models (from 5 to 48 HP).
• Efficiency improvement by 40% especially in low speed.
DC fan motor
DC motor efficiency
(
comparison with a conventional AC motor
)
200 300 400 500 600 700 800 900 1000
0
20
40
80
60
100
Efficiency (%)
Motor speed (
rpm
)
RSXYP-L
RSXYP-LRSXYP-L
AC motor
AC motorAC motor
There are few
heat losses.
Daikin has put comprehensive cutting-edge technologies into the VRV II, derived from its
Customer First policy and 20 years of experience with the VRV system.
The results are quieter operation, smaller units, sleeker design, and simpler installation
and maintenance, with less impact on the environment with higher COP.
The is now four times better.
Even earth friendly with a higher COP.
uieter
maller impler
leeker
a refrigerant with “ZERO” ozone layer-
depleting coefficient and no chlorone.
R410A is a new mixed refrigerant that
exhibits superior safety characteristics.
Even with a zero coefficient of ozone
layer depletion, R410A offers a better
performance to the conventional R22.
R410A...
    : http://splitoff.ru/tehn-doc.html