User`s manual
1817
Auto-swing Timer selector
High ceiling
application
Long life filter High fan
speed mode
Twin / triple /
double twin multi
application
(See page 19–20)
Program "Dry" Fan operation
mode
Mold resistant
treatment for filter
Anti-corrosion
treatment of
outdoor heat
exchanger fins
Self diagnosis
function
Auto-restart
Ceiling soiling
prevention
Fresh air intake
Filter sign
OPTIONAL
FUNCTIONS
Main functions for extra c om fort.
*
Please look for available functions for the model you select.
Greater of corrosion resistance
Construction.
Against acid corrosionAgainst s alt corrosion
Non-treated finNon-treated fin
Aluminium
PE fin PE fin
115–6 5–6
Corrosion
resistance grade
Aluminium
C orros ion res is tanc e a c rylic res in
Hydrophilic film
Also adapts to year-round cooling
RY200KU and RY250KU can adapt up to 0°C.
(Heat pump only)
200 and 250 models can be combined for
centralized, horizontal-series installation
Common width and depth make series installation easy.
RU08/10K models are available
in two types depending on
installation conditions
RU08/10KU models are factory shipped with
refrigerant charged for 5 meters of piping.
RU08/10K models are factory shipped with no
refrigerant charged.
Outdoor U nit
Two select
thermo-sensors
Draft preventive
function
Automatic Cool/Heat
Change-over
Hot start
R50G
R60G
RY50G
R
(
Y
)
71FU R
(
Y
)
100/125FU
R(Y)200KU R(Y)250KU
RU08K(U)
R125KU
RU06K
R
(
Y
)
140KU
RU10K(U)
RY60G
Flexible design
for large room or
multi-use
Piping can be drawn out from three directions - front, left side, or below.
Max. length Max. height
difference
Pre-charged
*1
50 m
(Equivalent length 70 m)
30 m
50 m
(Equivalent length 70 m)
30 m
5m
R(Y)200KU
5m
R(Y)250KU
Note:
1
Additional refrigerant charging is required if the refrigerant pipe is
longer than the indicated length.
Allowable refrigerant pipe length and height difference
R(Y)250KU
1280 mm
R(Y)200KU
1280 mm
R(Y)200KU
1280 mm
690 mm
Reduces installation space.
Equi pped with "hi gh s ta ti c pres s ure" fan.
Long hypotenuse blades with a gentle camber make the pressure rise on the
surface of the blades smooth and uniform, while suppressing break away of
the flow. As a result, it prevents rise in draft resistance produced due to lack of
open space behind the unit, and prevents air power from dropping.
"Air Flow Adjustment Guide" (standard equipment).
Cross-section of "Air Flow Adjustment Guide".
As show in the diagram, the air flow adjustment guide is factory set
so that exhaust air flow is inclined 30 degrees. The guide can be set
to direct the air flow to the left, right or down as well as upward, so
you can adjust the direction according to the place of installation.
Outdoor units include as standard equipment the "Air Flow Adjustment
Guide" which lets you set as desired the air flow in any one of four
directions in accordance with your layout. Cushions effect of air flow
striking against obstructions in front of the unit (walls,etc.) and prevents
"short circuits" from being formed.
Anti-Corrosion treatment of heat exchange fins.
The special acrylic precoated fin (PE fin) for anti-corrosion treatment
on the outdoor unit heat exchanger ensures greater resistance against
salt damage and atmospheric pollution than ever.
R125KUYALK has been added to the list of
models capable of operating with outdoor air
temperatures of up to 54°C.
Long hypotenuse blades
(Optimal camber)
500
50
30
°
( Applies to R71–125FU and 140KU )
( Applies to R71–125FU and 140KU )
( Applies to all outdoor units )
(Refer to the Specifications for details on other model)