Specifications
ED72-975 Operation Manual
BRC1E61 27
3P243520-1
English 35
Setting the schedule timer
Display method for the schedule timer settings
screen
Operation Method
The schedule timer can not be enabled when a centralized control is connected.
1
Return Setting
Timer setting
Schedule timer
Off reminder timer
Disable
Disable
2/2
Bring up the timer settings screen. Ɣ
(See page 34.)
Press Ɣ buttons to select the
Schedule timer on the timer settings
screen.
Press Menu/Enter button to display the
schedule timer settings screen.
Return Setting
Clock setting is not carried
out. Do you want to set?
Schedule timer
Yes No
Return Setting
Clock setting
Year 2008
Month 01
Day 01
Tuesday
00
:
00
Before setting the schedule timer, the Ɣ
clock must be set.
If the clock has not been set, a screen Ɣ
like the one on the left will appear.
Press
buttons to select Yes and
press Menu/Enter button.
Set the current year, month, day, and
time.
(See clock settings on page 48.)
2
Return Setting
Schedule timer
Enable/Disable setting
Condition setting
Holiday setting
Press Ɣ buttons to select the desired
setting items on the schedule timer
settings screen and press Menu/Enter
button.
01_EN_3P243520-1.indd 35 2/6/2009 5:50:06 PM
34 English
3
Set temperature
28°C
Cool
Return Setting
Selecting the desired ventilation mode Ɣ
and pressing Menu/Enter button enters
the settings and takes you back to the
basic screen.
(Pressing the Cancel button takes you back to the
previous screen without changing the ventilation
mode. )
Ventilation Mode
Automatic mode
Using information from the air conditioner (cooling, heating, fan,
and set temperature) and the total heat exchanger unit (indoor and
outdoor temperatures), mode is automatically changed between
Heat exchanger and Bypass.
Heat exchange mode
Outside air undergoes Heat exchange and is supplied to inside the room.
Bypass mode
Outside air is supplied to inside the room without undergoing heat exchange.
Timer Settings
Display method for timer settings screen
Operation Method
1
Return Setting
MainMenu
Set temp mode changeover
Airflow Direction
Quick Cool/Heat On/Off
Ventilation
Timer setting
Service Contact/Model info
1/2
Return Setting
Timer setting
Schedule timer
Off reminder timer
Disable
Disable
2/2
Display the main menu screen. Ɣ
(See page 26.)
Press Ɣ buttons to select
Timer setting on the main menu
screen.
Press Menu/Enter button to display the
timer settings screen.
Currently enabled/disabled is displayed.*
Set temperature
28°C
Cool
Return Setting
When either schedule timer or off reminder timer is Ɣ
enabled,
appears on the basic screen.
Menu Manipulation
01_EN_3P243520-1.indd 34 2/6/2009 5:50:06 PM