6 - 2 DEC102A51 - Digital input / output
6 - 2 - 1 Dimensional drawing
DEC102A51
3D047623
Mounting hole (*1)
(198)
(309)
325
335
70 70
70
70
C 1
6
4.5
40 40
140
40
80 40
325
UP
Spare hole (*1)
Mounting hole (*1)
Service entrance - wire lead-in port
(Approx. 10mm dia. x 6)
Fix the DEC102A51 firmly with
the installation screws (M4)
Spare hole (*1)
Front panel screw
DEC102A51
DEC102A51 DEC102A51
DEC102A51 DEC102A51
NOTES
1 Installation place
Install the unit indoors where it is not exposed to water
and dust or dirt.
Install the unit where both temperature and humidity do
not become high.
(Operating (available) temperature: -10~+40
°
C
Operating (available) humidity: 10~85%)
Connect the wiring to be connected in the field from the
lower surface side.
It is, therefore, necessary to make arrangements so as
not to attach other equipment within 80mm from the
lower surface of this equipment.
Install this equipment in a place in which only
authorized personnel can touch it.
2 Installation Direction
Install this equipment vertically to the floor surface. It should
be noted that if it is installed in horizontal direction, a
malfunction or failure may result.
3 Installation Method
Ensure that this equipment is installed with 4 screws (screw
size M4 min.).
4 Restrictions in continuous installation
In case several devices are set up and installation inside the
power board is carried out, each equipment installation space
and space between the wall surface and this equipment
should be left at least as shown to the left.
Power supply specifications 1~200-240V 50/60Hz
Rated power consumption 15W
Mass (Weight) 2.5kg
Case material Plated steel sheet
Case color Matting chrome