Technical data

14
• Control systems
• Individual control systems • Siesta Sky Air
Siesta Sky Air indoor units Controllers
ACQ*A cassette
ACQ-B
- Standard wireless remote controller in box of decoration panel ADP125A
- Optional wired remote controller ARCWB
AHQ*A ceiling suspended
- Standard wireless remote controller in box of indoor unit
- Optional wired remote controller ARCWB
ABQ*A concealed ceiling
ABQ*B
Standard wired remote controller (ARCWA) in box of indoor unit
Overview of available controllers for Siesta Sky Air
Specications
Dimensions (length x width x height) ARCWB: 0.15 m x 0.21 m x 0.04 m.
ARCWB comes standard with a 10 meter wire, which can be extended to maximum wire length of 15 meter. For reference: ARCWA comes standard with a 10 meter wire, which can-
not be extended.
ARCWB & ARCWA can only control one indoor unit at a time; group control not possible.
ARCWB: overview of features & dierences with ARCWA
Feature ARCWA ARCWB NEW
Standard with ABQ* A/B Option for AHQ*A and ACQ-A/B
1
Outlook
2 ON/OFF switch Standard Standard
3 Temperature setting
- default range 16-30°C Standard Standard
- optional range 20-30°C By dipswitch selection By dipswitch selection
- switch between °C and °F Standard Standard
4 Room temperature display Standard Not available
5 Room temperature sensor on remote controller Standard Standard
6 Cool / Fan dry / Heat / Auto Standard Standard
7 Sleep mode Standard Standard
8 Fan Speed selection Standard Standard
9 Delay timer 1, 2 & 4 hours delay 1 & 2 hours delay
10 7-days programmable timer Standard Standard
11 Real time clock display Standard Standard
12 Air swing selection
- ON/OFF swing mode Standard Standard
- Change swing option (draft/soil prevention or standard) Not available Standard
13 LCD display without backlight Standard Standard
14 Key lock Standard Standard
15 Error code indication Standard Standard
16
IR receiver to enable compatibility with wireless remote controller (disabled when
lock function is activated)
Standard Standard
17 Last state memory from indoor PCB Standard Standard
18 Silent mode Not available By dipswitch selection
19 Turbo mode Not available By dipswitch selection
20 Compressor test model (compressor force ON) Standard Standard
21 Daikin inverter error code Not available Standard
22 UART communication port (for Daikin protocol) Not available Standard
23 Backup battery Standard Standard