Specifications

ED04-805 Capacity Tables
Room Air Conditioners E-Series 21
FTXS35EVMA + RXS35EBVMA (50Hz 220-230-240V / 60Hz 220-230V)
3D054238A
Cooling
AFR 8.9
BF 0.24
INDOOR
OUTDOOR TEMPERATURE(°CDB)
20 25 30 32 35 40
EWB EDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
°C °C kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW
14.0 20 3.31 2.33 0.78 3.31 2.33 0.86 3.26 2.31 0.93 3.19 2.27 0.96 3.10 2.22 1.01 2.93 2.13 1.08
16.0 22 3.75 2.44 0.79 3.58 2.35 0.86 3.42 2.27 0.94 3.36 2.24 0.97 3.26 2.19 1.01 3.10 2.11 1.09
18.0 25 3.91 2.52 0.79 3.75 2.44 0.87 3.58 2.37 0.94 3.52 2.34 0.97 3.42 2.29 1.02 3.26 2.22 1.09
19.0 27 3.99 2.63 0.79 3.83 2.55 0.87 3.66 2.48 0.94 3.60 2.45 0.97
3.50 2.41 1.02 3.34 2.33 1.10
22.0 30 4.23 2.53 0.80 4.07 2.46 0.88 3.90 2.39 0.95 3.84 2.37 0.98 3.74 2.33 1.03 3.58 2.26 1.10
24.0 32 4.39 2.45 0.81 4.23 2.39 0.88 4.07 2.33 0.96 4.00 2.30 0.99 3.90 2.27 1.03 3.74 2.21 1.11
Heating
AFR 9.7
INDOOR
OUTDOOR TEMPERATURE(°CWB)
1050 610
EDB TCPITCPITCPITCPITCPI
°C kW kW kW kW kW kW kW kW kW kW
15.0 2.69 0.91 3.14 0.96 3.60 1.00 4.14 1.06 4.50 1.09
20.0 2.55 0.94 3.01 0.98 3.46 1.03
4.00 1.08 4.36 1.12
22.0 2.50 0.95 2.95 0.99 3.40 1.04 3.94 1.09 4.31 1.13
24.0 2.44 0.96 2.90 1.00 3.35 1.05 3.89 1.10 4.25 1.14
25.0 2.42 0.96 2.87 1.01 3.32 1.05 3.86 1.10 4.22 1.14
27.0 2.36 0.97 2.81 1.02 3.26 1.06 3.81 1.11 4.17 1.15
Symbols NOTE:
AFR : Air flow rate (m³/min.) 1. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 7.5m
Level difference : 0m
2. shows nominal (rated) capacities and power input.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C)
EDB : Entering dry bulb temp. (°C)
TC : Total capacity (kW)
SHC : Sensible heat capacity (kW)