Specifications
Piping Diagrams ED04-805
18 Room Air Conditioners E-Series
7.2 Outdoor Units
7.2.1 Cooling Only
RKS25/35EBVMA
7.2.2 Heat Pump
RXS25/35EBVMA
M
9.5CuT
MUFFLER
9.5CuT
LIQUID STOP
VALVE
GAS STOP
VALVE
FIELD PIPING
FIELD PIPING
(
6.4CuT
)
(
9.5CuT
)
REFRIGERANT FLOW
COOLING
DISCHARGE PIPE
THERMISTOR
MUFFLER
7.9CuT
FOUR WAY
VALVE
NORMALLY : OFF
COMPRESSOR
9.5CuT
ACCUMULATOR
7.9CuT
9.5CuT
PROPELLER FAN
9.5CuT
9.5CuT
7.0CuT
7.0CuT
OUTDOOR UNIT
HEAT EXCHANGER
4.8CuT
4.8CuT
HEAT EXCHANGER
THERMISTOR
MUFFLER
WITH
FILTER
OUTDOOR TEMPERATURE
THERMISTOR
6.4CuT 6.4CuT
MUFFLER
WITH
FILTER
MOTOR OPERATED
VALVE
MUFFLER
WITH
FILTER
6.4CuT
φ
. 4.0
×
ID. 2.0CuT
3D047318F
M
9.5CuT
DISCHARGE PIPE
THERMISTOR
MUFFLER
PROPELLER FAN
7.9CuT
7.9CuT
COMPRESSOR
FOUR WAY
VALVE
ON : HEATING
9.5CuT
ACCUMULATOR
9.5CuT
9.5CuT
7.0CuT
7.0CuT
OUTDOOR UNIT
HEAT EXCHANGER
HEAT EXCHANGER
THERMISTOR
OUTDOOR TEMPERATURE
THERMISTOR
4.8CuT
4.8CuT
MUFFLER
WITH
FILTER
6.4CuT 6.4CuT
MUFFLER
WITH
FILTER
MOTOR OPERATED
VALVE
MUFFLER
9.5CuT
MUFFLER
WITH
FILTER
6.4CuT
LIQUID STOP
VALVE
GAS STOP
VALVE
FIELD PIPING
FIELD PIPING
(
6.4CuT
)
(
9.5CuT
)
φ
. 4.0
×
ID. 2.0CuT
REFRIGERANT FLOW
COOLING
HEATING
9.5CuT
3D047316J