Specifications

14
3 - THE DOMESTIC HOT WATER TANK
Field supply1.
Hot water connection (H)2.
Pressure relief valve connection3.
Pressure relief valve (field supply)4.
Electrical box5.
Electrical box lid6.
Recirculation hole7.
Thermistor socket8.
Flow inlet connection (F) (from main unit)9.
Heat exchanger coil10.
Return outlet connection (R) (to main unit)11.
Cold water connection (C)12.
Threaded thermistor hole for use with solar kit option. 13.
(Refer to the Installation manual EKSOLHWBAVJU).
Temperature and pressure relief valve connection
14.
Thermal protectors (Q2L, Q3L)15.
Booster heater16.
Flow direction17.
Available in 2 capacities: 50 and 80 >
gallons for floor mounted installation.
Stainless steel design.
>
1 37/64” cfc-free insulation material (polyurethane) > .
Contains 2 heating elements: a heat
>
exchanger at the bottom where the hot
water from the hydrobox circulates and an
extra 3 kW electric heater at the top.
A thermistor in the hot water tank controls a 3-way
>
valve and/or booster heater via the hydrobox.