Specifications

13
2 - DAIKIN ALTHERMA
TM
MONOBLOC AIR-TO-WATER HEAT PUMP
High efficiency compressor1.
Expansion tank2.
Tank with back up heating3.
Pressure gauge (water circuit)4.
Refrigerant connection5.
All hydronic parts are located within the outdoor unit >
H >
2
O piping between outdoor unit and indoor heating apparatus
The Daikin Altherma
TM
monobloc is available in
different versions
- heating only or heating and cooling
- with bottom plate heater
- single phase
- 35MBH, 48MBH, or 54MBH
Built-in electric back-up heater
> for additional
heating during extremely cold outdoor
temperatures. The Daikin Altherma Monobloc
is standard equipped with a 6 kW back-up
heater, which can be adjusted to 3 kW.
If necessary, an “in line” back-up heater of 6 kW can be
mounted indoors (also adjustable to 3 kW or 3.5 kW)
The
> scroll-compressors provided are designed as
a compact, robust, low-noise device to guarantee
optimal operational reliability (no valves and
built-in swing-link coupling) and efficiency
(through a low initial flow and a constant
compression ratio).
1 5
3
4
2
TECHNICALLY
DID YOU KNOW…
In order to protect the water pipes
from freezing up during winter,
insulation is provided for all hydronic
components and special software has
been applied to activate the pump
and back-up heater if necessary.
This prevents the water temperature
from dropping below freezing point
and can minimize the need for the
addition of glycol to the water pipes.