Specifications
27
DANGER
WARNING
CAUTION
・・・
Failure to observe the instruction may cause an imminent hazardous situation that may result in personal death or serious injury.
・・・
Failure to observe the instruction may result in personal death or serious injury.
・・・
Failure to observe the instruction may result in personal injury or damage to the property.
Signs and
Instructions
Supporting
information
Supporting information
●Instructions for safe operation
*Before operating this unit, be sure to read the operation manual and properly understand it.
Notes for handling
Notes for handling
[ DANGER]
[ DANGER]
[ DANGER]
[ DANGER]
[
WARNING
]
[
WARNING
]
[
CAUTION
]
[
CAUTION
]
[
CAUTION
]
ʱ
Use the equipment only in accordance with the intended specifications(specified in brochure, specification sheet, operation manual, caution plate).
ʲNever operate the equipment in an explosive atmosphere
ʳDo not disassemble, repair or modify the equipment by yourself.
ʴ
Always comply with the laws and regulations for safety(Industrial Safety and Health Law, Fire Defense Law, JIS B 8361 Guidelines of Hydraulic System).
ʵCaution in the event of refrigerant leak
・Ventilate a room adequately (to avoid the risk of suffocation).
・Avoid direct contact of the refrigerant with skin (to avoid the risk of frost injury).
・
In the event of inhalation of a great deal of refrigerant, contact with skin, and refrigerant in the eye, seek medical attention immediately.
ʶ
In the event of an abnormal condition, stop operation promptly, investigate the cause of the problem and take appropriate remedial measures.
ʷ
Do not use the unit in atypical environments (locations subject to high temperatures, high humidity, or
a lot of dust, contamination, particulate matter, steam, oil mist or corrosive gases: H
2
S,SO
2
,
NO
2
or CL
2
).
ʸ
Install a flow switch and temperature switch on the main machine to protect the main shaft and others.
ʹDo not get on the equipment or place an object on the equipment.
[ DANGER]
[
WARNING
]
[
CAUTION
]
[
CAUTION
]
①
When hoisting the equipment, check its weight and use the eye plates and hangers on the equipment properly.
② Do not get approach the equipment while it is being hoisted and moved.
③ When moving the equipment, take appropriate measures for fall prevention.
④
Do not tilt the equipment 30 degrees or more while transporting the equipment (including during storage).
[
CAUTION
]
[
CAUTION
]
[
CAUTION
]
[
CAUTION
]
①
Check to see that the main machine is in a safe status (not activated) before starting the trial run.
②
Check to see that the oil piping and electric wiring are correctly connected to the main machine and that there is no looseness in connections and joints.
③
Disable the operation lock of the equipment (Oil Cooling Unit) before starting the main machine.
④ C
heck to see that the required amount of oil is in the oil piping system and that the piping is not blocked in the middle.
[ DANGER]
[
WARNING
]
[
CAUTION
]
① Do not splash water or liquid on the equipment.
② Do not push your finger or an object into gaps of the equipment.
③ Do not touch the heated exhaust port of the equipment.
[ DANGER]
[ DANGER]
[ DANGER]
[ DANGER]
[
CAUTION
]
[
CAUTION
]
[
CAUTION
]
[
CAUTION
]
[
CAUTION
]
①
Perform maintenance and inspection with the equipment kept open. Working in a closed status may result in suffocation due to the leak of refrigerant.
② Always turn off the main power supply before starting maintenance and inspection.
③
Wait for five minutes after turning off the main power supply and start maintenance and inspection operation.
④ Do not operate the equipment with the cover of the equipment opened.
⑤
Wear protective gear such as gloves and an eye protector when performing maintenance, inspection and cleaning.
⑥ Clean the air filter periodically (once every two weeks in general).
⑦ Keep oil cleanliness to NAS 10 level or less according to the pollution level.
ʸCheck the oil level in the tank and ensure that it is between the yellow line and the red line.
ʹ
Inspect the underneath (drain pan) of the oil cooling unit once every six months, and if oil has accumulated, discharge it through the oil drainage port.
[
WARNING
]
[
CAUTION
]
① Install the equipment on a rigid, level foundation and secure it appropriately.
② Do not place an object near the suction port and discharge port of the equipment.
[ DANGER]
[ DANGER]
[ DANGER]
[ DANGER]
[
WARNING
]
[
CAUTION
]
[
CAUTION
]
①
Wiring and piping installation should be performed by a person with specialized knowledge and skills.
②
Always use a commercial power supply for the power source. (The use of an inverter power supply may cause burn damage).
③
Connect the wiring for power supply in accordance with the electric wiring instruction diagram of the specification sheet and operation manual.
④ Ground the equipment properly.
⑤ Install the wiring in accordance with the standard by checking the electric schematic diagram.
⑥
Always install a dedicated breaker (molded case circuit breaker) appropriate for the capacity of Oil Cooling Unit on the main power supply on site.
⑦
Check to see that the oil piping has the pressure resistance of 1MPa or more and install the piping appropriately.
2 Instructions for transportation
3 Instructions for installation
4 Instructions for wiring and piping installation
5 Instructions for trial run
6 Instructions during operation
7 Instructions for maintenance and inspection
1 General instructions