Performance
Cooling (Btu/hr)
Rated 18,000
Operating Range 14°F – 115°F
Rated Cooling Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Heating (Btu/hr)
Rated 18,900
Operating Range 5°F – 60°F
Rated Heating Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Submittal Data Sheet 2MXS18NMVJU
2 Port, 1.5-Ton Outdoor Heat Pump
Efficiency
SEER EER HSPF COP
Non-Ducted 18.9 12.5 10.7 4.33
Ducted 14 9.5 8.2 3.34
Mixed 16.45 11 9.45 3.84
Electrical
208/60/1 230/60/1
System MCA 15.8 15.8
System MFA 20 20
Compressor RLA 14.0 14.0
Outdoor fan motor FLA .37 .37
Outdoor fan motor W 56 56
MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A)
RLA: Rated load amps (A) W: Fan motor rated output (W)
Piping
Liquid (in) ¼ x 2
Gas (in)
3/8 x 1,
½ x 1
Drain (in) 11/16
Max. System Piping Length (ft) 164
Max. Interunit Piping Length (ft) 82
Max. Height Difference – IDU to ODU (ft) 49.25
Max. Height Difference – IDU to IDU (ft) 24.625
Chargeless (ft) 98.4
Additional Charge of Refrigerant (oz/ft) .21
Outdoor Specifications
Compressor Hermetically Sealed Swing Type
Refrigerant R-410A
Factory Charge (Lbs) 3.86
Refrigerant Oil PVE (FVC50K)
Airflow Rate (cfm)
Cooling
Heating
H 2,150
H 2,150
M 2,150
M 2,150
L 1,953
L 1,953
Sound Pressure Level (dBA) 50 / 51
Dimensions (H × W × D) (in) 28-15/16 × 34-1/4 × 12-5/8
Weight (Lbs) 123
Job Name:
Tag#
Complete warranty details available from your local dealer or at
www.daikincomfort.com. To receive the 12-Year Parts Limited
Warranty, online registration must be completed within 60 days of
installation. Online registration is not required in California or Quebec.
If product is installed in a commercial application, limited warranty
period is 5 years
.