User Guide
Table Of Contents
23
Step 4 Configure thermal temperature monitoring parameters.
Table 5-1 Description of temperature monitoring parameter
Parameter Description
Period
Define a period during which the alarm settings are valid.
1. Click
Setting
, and the period setting interface is displayed.
2. Configure period.
●
Method 1: Press and drag the left mouse button on the
time line.
●
Method 2: Click
Setting
for the day in the week you want
to configure, and then configure periods as needed (6
periods are available).
3. Click
Save
.
Record Max. Temperature
Set the period during which the camera will monitor the
temperatures and capture the images when the temperature
reaches the highest value. It is 3 s by default. When the value is 0,
it means that the camera will capture the image when the target
appears in the detection area,
Temperature Report
Enable temperature report, and the temperature is displayed on
the screen of the Device in real time.
High Temperature Warning
Enable the temperature warning, and then set the warning
threshold. It ranges from 1 °C to 43 °C. When the monitored
temperature is higher than or equal to this value, an alarm is
triggered. It is 37.3 °C by default.
Low Temperature Warning
Enable the low temperature warning, and then set the warning
threshold. It ranges from 1 °C to 43 °C. When the monitored
temperature is lower than or equal to this value, an alarm is
triggered. It is 27 °C by default.
Temp Lower Limit
Set the lower limit of the body temperature. The camera only
monitors temperatures that are higher than or equal to this value.
It is 43 °C by default.
Temp Upper Limit
Set the upper limit of the body temperature. The camera only
monitors temperatures that are lower than or equal to this value.
It is 32 °C by default.
Nearest Temperature
Distance
The camera detects the temperature of the targets who are
within the highest and lowest detection range. It takes effect
after distance detection is enabled. The nearest temperature
distance is 50 cm, and the furthest temperature is 200 cm by
default.
Select
Setting
>
Smart Thermal
>
Smart Channel
to enable
distance detection.
Furthest Temperature
Distance
Step 5 Click
Save
.
5.4 Configuring Smart Channel
Step 1 Select
Setting
>
Smart Thermal
>
Smart Channel
.