Operation Manual

Dahua Network Camera Web 3.0 Operation Manual
102
Application scene: it can be applied to the scene where the target is sparse and there is no obvious and
frequent light change. False alarm will be increased in the scene where the target density is high and
there is frequent obstruction; the false alarm will be increased in the scene where there are more people
staying. As for the detection area, try to make it simple, the function is not suitable for the area which is
too complicated.
Step 1
Select Setup > Event > IVS > IVS and the system will display the interface of IVS.
Step 2
Click to set rule name and select rule type as Missing Object, which is shown in Figure 5-73.
Figure 5-73
Step 3
Click Draw Rule to draw an area in the monitoring scene.
Step 4
Click “Draw Target” to draw the size model of filtered target in the video image.
Step 5
It is to set the parameters of missing object, please refer to the following sheet for more details.