Wireless Water Leak Detector User’s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO., LTD. V1.0.
User’s Manual Foreword General This manual introduces the installation, functions and operations of the Wireless Water Leak Detector (hereinafter referred to as the "water leak detector"). Read carefully before using the device, and keep the manual safe for future reference. Safety Instructions The following signal words might appear in the manual. Signal Words Meaning DANGER Indicates a high potential hazard which, if not avoided, will result in death or serious injury.
User’s Manual the electronic version and the paper version. ● All designs and software are subject to change without prior written notice. Product updates might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation. ● There might be errors in the print or deviations in the description of the functions, operations and technical data.
User’s Manual Important Safeguards and Warnings This section introduces content covering the proper handling of the water leak detector, hazard protection, and protection of property damage. Read carefully before using the water leak detector, and comply with the guidelines when using it. Operation Requirements ● Make sure that the power supply of the water leak detector works properly before use. ● Do not pull out the power cable of the water leak detector while it is powered on.
User’s Manual Table of Contents Foreword ........................................................................................................................................................................................................I Important Safeguards and Warnings............................................................................................................................................ III 1 Introduction ...........................................................................
User’s Manual 1 Introduction 1.1 Overview Wireless Water Leak Detector can be used to detect water leaks in indoor pipes, baths, sinks, washing machines, and dishwashers. It triggers alarms and provides timely notifications to keep you up to date on ongoing events. It is easy to install and does not require wiring. It also provides communication security, supporting the use of wireless communication with encryption technology. 1.
User’s Manual Type General Parameter Description Frequency Hopping Yes Power Supply CR123A× 1 Battery Life 3 years when triggered once a day. Power Consumption Max 144 mW Operating Temperature –10 °C to +55 °C (+14 °F to +131 °F) (indoor) Storage Temperature –10 °C to +55 °C (+14 °F to +131 °F) Operating Humidity 10%–90% (RH) Storage Humidity 10%–90% (RH) Product Dimensions 84.7 mm× 84.7 mm× 32.5 mm (3.33" × 3.33" × 1.28") Packaging Dimensions 135.0 mm× 98.0 mm× 56.0 mm (5.32" × 3.
User’s Manual 2 Checklist Figure 2-1 Checklist Table 2-1 Checklist No. Item Name Quantity No.
User’s Manual 3 Appearance Figure 1-1 Appearance Table 1-1 Structure No. Name Description ● Press and hold the button for 2 seconds, and then the device is powered on, and the system enters pairing mode. 1 Indicator Solid on for 2 seconds: Pairing successful. Slowly flashes for 3 times: Pairing failed. ◇ ◇ ● Flashes green quickly for 100 seconds, and then off: Sensitivity mode. ● Solid on for 0.4 seconds: An alarm event was triggered.
User’s Manual 4 Adding the Wireless Water Leak Detector to the Hub Before you connect water leak detector to the hub, install the DMSS app to your phone. This manual uses iOS as an example. ● Make sure that the version of the DMSS app is 1.99.300 or later, and the hub is V1.001.0000004.0 or later. ● Make sure that you have already created an account, and added the hub to DMSS. ● Make sure that the hub has a stable internet connection. ● Make sure that the hub is disarmed.
User’s Manual 5 Installation Water leak detector supports all-in-one installation and split mount with screw or adhesive tape. 5.1 All-in-one Installation You can adjust the height of the positive probe to adjust the sensitivity first, and then place the water leak detector at a place where the water is likely to leak directly. Step 1 Adjust the height of the positive probe with screw to adjust the sensitivity.
User’s Manual Figure 5-3 Place the water leak detector 5.2 Split Mount with Screw You can use the screw to install the water leak detector. Step 1 Rotate the back cover to remove it from the water leak detector. Figure 5-4 Remove the back cover Step 2 Drill 2 holes into the wall according to the hole positions of the water leak detector, and then put the expansion bolts into the holes. Figure 5-5 Remove the back cover Step 3 Attach the water leak detector to the back cover.
User’s Manual Figure 5-6 Attach the water leak detector to the back cover Step 4 Adjust the height of the positive probe with screws to adjust the sensitivity. Figure 5-7 Adjust the height of the positive probe 5.3 Split Mount with Adhesive Tape You can use adhesive tape to install the water leak detector. Step 1 Rotate the back cover to remove it from the water leak detector.
User’s Manual Figure 5-8 Remove the back cover Step 2 Attach the water leak detector to the wall with the double-sided adhesive tape. Figure 5-9 Remove the back cover Step 3 Attach the water leak detector to the back cover.
User’s Manual Figure 5-10 Attach the water leak detector to the back cover Step 4 Adjust the height of the positive probe with the screw to adjust the sensitivity.
User’s Manual 6 Configuration You can view and edit general information of the water leak detector. 6.1 Viewing Status On the hub screen, select a water leak detector from the peripheral list, and then you can view the status of the water leak detector. Table 6-1 Status Parameter Value Temporary Deactivate The status for whether the functions of the repeater are enabled or disabled. ● : Enable. ● : Disable. Signal Strength The signal strength between the hub and the water leak detector. ● : Low.
User’s Manual Table 6-2 Parameter description Parameter Description ● View water leak detector name, type, SN and device model. Device Configuration ● Edit water leak detector name, and then tap Save to save configuration. Area Select the area to which the water leak detector is assigned. Whether send sensor information to the alarm hub. ● Tap Enable, and then the water leak detector will send alarm Temporary Deactivate messages to the hub. Enable is set by default.
User’s Manual Appendix 1 Cybersecurity Recommendations Cybersecurity is more than just a buzzword: it’s something that pertains to every device that is connected to the internet. IP video surveillance is not immune to cyber risks, but taking basic steps toward protecting and strengthening networks and networked appliances will make them less susceptible to attacks. Below are some tips and recommendations from Dahua on how to create a more secured security system.
User’s Manual 1024–65535, reducing the risk of outsiders being able to guess which ports you are using. 6. Enable HTTPS We suggest you to enable HTTPS, so that you visit Web service through a secure communication channel. 7. MAC Address Binding We recommend you to bind the IP and MAC address of the gateway to the device, thus reducing the risk of ARP spoofing. 8.
User’s Manual device. More information Please visit Dahua official website security emergency response center for security announcements and the latest security recommendations.