Use the following data to install the camera in the optimal position: 
Camera 
Resolution 
Focal Length 
(mm) 
Installation 
Depression Angle 
Max Installation 
Height (m) 
Max Monitoring Distance 
(m) 
200W 
2.8  45°  4.5  4 
3.6  45°  4.5  4.5 
6  45°  5  6.5 
8  45°  5.5  8.5 
12  45°  5.5  12 
400W 
2.8  45°  3.8  2.7 
3.6  45°  4  3.3 
6  45°  4.4  4.9 
500W 
2.8  45°  4.4  3.5 
3.6  45°  4.8  4 
6  45°  5.4  5.8 
8  45°  5.6  7 
12  45°  5.5  10 
6.3.4 Configuring the People Counting Function 
  Log into the camera’s web interface and select the SETTING tab. 
  Click Event menu item, at the left side of the screen. Then, click SMART PLAN. 
The SMART PLAN interface is displayed. 
  Select the People Counting option (note that not all cameras offer all of analytic functions): 
  Click Save to choose the plan. 
  Click People Counting to access the People Counting function settings. 
  Select In Area No. or People Counting from the Rule Type drop-down menu. 