Parameter 
Description 
Send Email 
Select Send Email to issue an email when an alarm is triggered. Set email 
addresses in the Network -> SMTP (email) setting box. 
Snapshot 
Select Snapshot to record a snapshot of the scene that shows the tripwire 
violation. 
6.2.9 Loitering Detection 
The loitering detection function monitors a defined area for the presence of an object that 
remains in the area longer than a specified amount of time. The object must be in motion 
during the surveillance period, the function will not trigger an alarm for a stationary object. The 
object must move by at least its own width at least every two seconds during the surveillance 
duration for the function to trigger an alarm. 
Parameter 
Description 
Period 
Configure working period, and the rule takes effect only within this period. 
7.  Click Setting to open the Period setting window. 
8.  Configure each period. 
A: Press and hold the left mouse button, and then drag at the periods you 
need. 
B: Click the Setting behind the week day you need, and then the week day 
in the period setting box shows red color, select and configure the 
periods you need, and you can configure 6 periods in one week day 
at most. 
9.  Click OK. 