Use the following data to install the camera in the optimal position:
Camera
Resolution
Focal Length
(mm)
Installation
Depression Angle
Max Installation
Height (m)
Max Monitoring Distance
(m)
200W
2.8 45° 4.5 4
3.6 45° 4.5 4.5
6 45° 5 6.5
8 45° 5.5 8.5
12 45° 5.5 12
400W
2.8 45° 3.8 2.7
3.6 45° 4 3.3
6 45° 4.4 4.9
500W
2.8 45° 4.4 3.5
3.6 45° 4.8 4
6 45° 5.4 5.8
8 45° 5.6 7
12 45° 5.5 10
6.3.4 Configuring the People Counting Function
Log into the cameras web interface and select the SETTING tab.
Click Event menu item, at the left side of the screen. Then, click SMART PLAN.
The SMART PLAN interface is displayed.
Select the People Counting option (note that not all cameras offer all of analytic functions):
Click Save to choose the plan.
Click People Counting to access the People Counting function settings.
Select In Area No. or People Counting from the Rule Type drop-down menu.
Refer to the following sections for specific instructions for each People Counting function.